JLG 1532E2 Service & Maintenance page 62

Hide thumbs Also See for 1532E2:
Table of Contents

Advertisement

SECTION 2 - PROCEDURES
TOP LEVEL MENU
ACCESS LEVEL
PERSONALITIES
2-50
Table 2-9. Analyzer Menu Structure
ITEM TO BE VIEWED
SUB LEVEL MENU
OR CHANGED
CODE
DRIVE
ACCEL
DECEL
CREEP
LOW MAX
HIGH MAX
ELEVATED MAX
POSI-TRAC
HIGH DRIVE AMP
HIGH DRIVE
LIFT
ACCEL
DECEL
CREEP
MAX UP
MAX DOWN N/A
– JLG Sizzor –
DESCRIPTION DISPLAY
Displays the current access level
Level 3 - Personalities cannot be changed
Level 2 - Most personalities can be changed
Level 1 - All personalities can be changed
Allows access level password to be entered
Use LEFT/RIGHT to select digit
Use UP/DOWN to change digit
Use ENTER to update access level
Displays/adjusts drive acceleration
Displays/adjusts drive deceleration
Displays/adjusts minimum drive speed
Displays/adjusts maximum "low" drive speed
NOTE: Used when high drive not selected
Displays/adjusts maximum "high" drive speed
NOTE: Used when high drive not selected
Displays/adjusts maximum drive speed elevated
NOTE: Used when elevation or pothole cutout switches are
limiting max speed
NOTE: Only adjustable in access level 1
Displays/adjusts posi-trac engaged time-out
Displays /adjusts high drive motor overload current
NOTE: Only adjustable in access level 1
Displays/adjusts high drive motor overload time-out
Displays/adjusts lift acceleration
Displays/adjusts lift deceleration
Displays/adjusts minimum lift (up) speed
Displays/adjusts maximum lift (up) speed
Displays if there is no lift down (gravity)
Displays/adjusts for power down machines for maximum lift
down speed
3120855

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1932e22032e22632e22646e23246e2