SECTION 2 - PROCEDURES
NOTE: Refer to the appropriate Machine Personality Set-
tings Table, and the Machine Setup Table in the JLG
Service Manual for the recommended factory set-
tings. Refer to the JLG part number of the controller,
printed on the front label, to select the correct table
in the manual.
NOTE: Password 33271 will give you access to level 1,
which will permit you to change all machine person-
ality settings. There are some settings that JLG
strongly recommends that you do not change. These
settings are so noted below:
ELEVATION CUTBACK
POSITRAC TIMEOUT
HIGH DRIVE CURRENT LIMIT
HIGH DRIVE TIME LIMIT
CHANGING THESE SETTINGS MAY ADVERSELY AFFECT THE
PERFORMANCE OF YOUR MACHINE.
WHEN INSTALLING A NEW SMART SYSTEM CONTROLLER ON
THE MACHINE, ELECTRICAL SILICONE GREASE, JLG PART
NUMBER 0100076 OR 7016397, MUST BE APPLIED TO THE BACK
OF THE CONTROLLER.
IT IS A GOOD PRACTICE TO AVOID PRESSURE-WASHING ELEC-
TRICAL/ELECTRONIC COMPONENTS. SHOULD PRESSURE-
WASHING BE UTILIZED TO WASH AREAS CONTAINING ELECTRI-
CAL/ELECTRONIC COMPONENTS, JLG INDUSTRIES, INC. REC-
OMMENDS A MAXIMUM PRESSURE OF 52 BAR (750 PSI) AT A
MINIMUM DISTANCE OF 30.5 CM (12 IN) AWAY FROM THESE
COMPONENTS. IF ELECTRICAL/ELECTRONIC COMPONENTS
ARE SPRAYED, SPRAYING MUST NOT BE DIRECT AND BE FOR
BRIEF TIME PERIODS TO AVOID HEAVY SATURATION.