Configuration Digit
5
(FUNCTION CUTOUT)
6
(GROUND ALARM)
7
(DRIVE CUTOUT)
8
(ARM GUARDS))
9
(Flash Codes)
3120855
Table 2-6. Machine Configuration Programming Information
Number
0
No function cutout installed.
1
Overload switch for French, Japanese machines. — Cuts out all functions. Sounds
platform alarm for two seconds on, two seconds off, while operator tries to perform the
function that has been cut out (provided the platform alarm is installed).
0
No ground alarm installed.
1
Descent alarm. — Sounds when LIFT DOWN is active.
2
Travel alarm. — Sounds when DRIVE function is active.
3
Motion alarm. — Sounds whenever the DRIVE, LIFT or DECK function is active.
0
No drive cutout switch installed.
1
Cuts out DRIVE when deck is elevated above a predetermined elevation (varies with
machine model).
0
No arm guard cutout.
1
European (CE Specification) machines — LIFT DOWN cutout must activate when the
gap between the arms is 5 in. to 8 in. (13 cm to 20 cm). Here it will cut out LIFT DOWN
and sound the platform alarm for 1/2 second on, 1/2 second off, and repeat this for
three seconds. After three seconds, the operator must re-select the LIFT function and
continue to operate LIFT DOWN. If the wires to the limit switch used to detect the deck
height are cut or the switch has failed, the platform alarm will sound as mentioned. The
operator can re-select the LIFT function and then LIFT DOWN for ten seconds, at
which time it will cut out again and the process must be repeated.
0
LED Only
1
LED and lamps in platform control box
2
LED and alarm
3
LED, lamps in control box and alarm
Description
– JLG Sizzor –
SECTION 2 - PROCEDURES
Default Setting
Before
Programming
0
0
0
0
0
2-43