JLG 1532E2 Service & Maintenance page 61

Hide thumbs Also See for 1532E2:
Table of Contents

Advertisement

TOP LEVEL MENU
ACTIVATE TESTS
3120855
Table 2-9. Analyzer Menu Structure
ITEM TO BE VIEWED
SUB LEVEL MENU
OR CHANGED
DATALOG
ON
DRIVE
LIFT
DECK
PUMP
RENTAL
ERASE RENTAL
(YES:ENTER,NO ESC)
MAX. TEMP
MIN. TEMP
MAX BATTERY
VERSIONS
ASPC
ANALYZER
YES:ENTER,NO:ESC
RUN SYSTEM TEST
(Machine must be fully
lowered before run-
ning systems test)
– JLG Sizzor –
SECTION 2 - PROCEDURES
DESCRIPTION DISPLAY
Displays total controller on time
NOTE: Up to four minutes lost at switch-off
Displays total controller drive operation time
Displays total controller lift operation time
Displays total controller deck operation time
NOTE: Not displayed if POWER DECK = NO
Displays total controller pump running time
NOTE: Includes drive, lift up, deck and steer
Displays total controller pump running time
NOTE: Can be reset
Not available in level 3
ENTER resets rental datalog time to zero
Displays maximum measured heatsink temperature
Displays minimum measured heatsink temperature
Displays maximum measured battery voltage
Displays controller software version
Displays analyzer software version
Not available once tests are activated
ENTER activates system test
NOTE: Cannot be done while controller is use (trigger switch
closed)
ENTER starts system test
Not available until tests are activated
Displays messages while system test runs
Some messages are prompts, requiring user intervention
ENTER can be pressed if a fault has been noted and to con-
tinue the system test.
NOTE: A flashing message is critical, and prevents the sys-
tem test from running.
2-49

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1932e22032e22632e22646e23246e2

Table of Contents