Ac Input Cable; Dry Contacts Output; Ev Charge Cable Specifications; Ac Output Specifications - ABB Terra AC Installation Manual

Hide thumbs Also See for Terra AC:
Table of Contents

Advertisement

Technical data
Required torque
Parameter
Strip length
Terminal connections
Wire AWG and cross section: based on a copper wire type
10.12.5

Dry contacts output

The dry contacts input is the single contact in the EVSE.
Parameter
EVSE connector type
Wire size for the terminal block plug (al-
lowed maximum)
Wire size for the terminal block plug
(recommended)
Required torque
Strip length
Terminal connections
Contact rated load
The wire AWG and cross section are based on a copper wire type.
10.12.6

EV charge cable specifications

Parameter
Length
10.13

AC output specifications

10.13.1
AC output specifications
Parameter
AC output voltage range
Connection standard
52
0.5 Nm
Specifications
5 mm
PE/Shield: Contact input terminal 1
or 2
Configuration input: Contact input
terminal 2 or 1
Specifications
Terminal block plug and screws
2
2.5 - 0.5 mm
(Europe)
12 - 30 AWG (North America)
2
20 AWG (0.75 mm
) minimum
0.5 Nm
5 mm
Configuration output dry contact 1:
Contact output terminal 1
Configuration output dry contact 2:
Contact output terminal 2
125 VAC/30VDC at 3A
Value [m]
8
Specification
240 V AC (1 phase)
Type 1 cable according to SAE J1772