Technical data
10.11
General logic interface specifications
Parameter
Connectivity
Smart meter communication
Ethernet
Extra ethernet (daisy chain)
WiFi (WAN)
Bluetooth
RFID
Compatible mobile device operating sys-
tems
10.12
Cable specifications
10.12.1
AC input cable
Parameter
EV charger station connection type
Wire size for the terminal (PE)
Wire size for the terminal (L1,L2)
Strip length
Cable shielding (optional)
Diameter of the phase conductors
Diameter of the PE conductor
•
•
50
Consult your local electrical codes for the correct wire size, based on the envi-
ronment, the conductor type and the rating of the EVSE.
The wire AWG is based on the copper wire type.
Specification
Mobile communication with Nano-SIM
socket type M2M (Machine To Machine)
•
2G (GSM)
•
3G (WCDMA)
•
4G (LTE)
Modbus RTU (RS485)
Modus TCP/IP
1x 10/100 BaseT, RJ45 Socket
1x 10/100 BaseT, RJ45 Socket
IEEE 802.11 b/g/n, 2.4 GHz
BLE 5.0
MIFARE ISO/IEC 14443A RFID cards
•
Android 4.4 or higher
•
iOS8 or higher
Specification
Terminal /lugs and screws
8 AWG
2 AWG
14 mm(L1,L2)/8.5mm(PE)
The local rules require shielded cables.
The cable shielding must be connected
to the PE rail at the two ends of the ca-
ble.
Refer to the local rules.
The same as te diameter of the phase
conductors