Eaton SVX9000 Quick Start Manual

Eaton SVX9000 Quick Start Manual

Adjustable frequency drive
Hide thumbs Also See for SVX9000:

Advertisement

SVX9000 Drives
Quick Start Guide
Effective November 2011
Supersedes December 2003
CONTENT
STEP 1 — Keypad Operation Overview
STEP 2 — Standard Wiring Diagrams and Connections
STEP 3 — Start-Up Wizard
STEP 4 — Operating and Programming Menu
Navigation
STEP 5 — Faults and Warning Indication
STEP 6 — Monitoring Menu

Advertisement

loading
Need help?

Need help?

Do you have a question about the SVX9000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Eaton SVX9000

  • Page 1 SVX9000 Drives Quick Start Guide Effective November 2011 Supersedes December 2003 CONTENT STEP 1 — Keypad Operation Overview STEP 2 — Standard Wiring Diagrams and Connections STEP 3 — Start-Up Wizard STEP 4 — Operating and Programming Menu Navigation STEP 5 — Faults and Warning Indication...
  • Page 2: Keypad Operation Overview

    LCD Status Indicators Indicator Description Indicates that the SVX9000 is running and controlling the load. Blinks when a stop command has been given but the SVX9000 is still ramping down. Counterclockwise Operation The output phase rotation is BAC, corresponding to counterclockwise rotation of most motors.
  • Page 3: Menu Navigation

    Used to set the password (if defined) when leaving the “Operate” menu. • scroll through the “Active Faults” menu when the SVX9000 is stopped. Menu Navigation Navigation Tips To navigate within one level of a menu, use the up and down arrows.
  • Page 4 1 – 15 hp 480V 1-1/2 – 30 hp Control Board L2 L3 (Optional) External External RFI-Filter Filter (Optional) (Optional) L2 L3 SVX9000 Power and Motor Wiring for Low Horsepower Drives (1 – 30 hp) SVX9000 Drives MN04003009E—November 2011 www.eaton.com...
  • Page 5 20 – 30 hp 480V 40 – 250 hp Control Board L2 L3 (Optional) External External RFI-Filter Filter (Optional) (Optional) L2 L3 SVX9000 Power and Motor Wiring for Large Horsepower Drives (20 – 250 hp) SVX9000 Drives MN04003009E—November 2011 www.eaton.com...
  • Page 6 Jumper Block X3: CMA and CMB Grounding CMB connected to GND CMA connected to GND CMB isolated from GND CMA isolated from GND CMB and CMA internally connected together, isolated from GND = Factory default. SVX9000 Drives MN04003009E—November 2011 www.eaton.com...
  • Page 7: Startup Wizard

    Remote Reference “I/O Terminal” “Keypad” “AI1” Input Phase Supv Repeat Setup? Setup Done “Fault, Coast” <No Yes> Press Enter Copy Parameters Up to Keypad Up to Keypad <No Yes> <No Yes> Wait Output Frequency “0.00” Hz SVX9000 Drives MN04003009E—November 2011 www.eaton.com...
  • Page 8: Main Menu Navigation

    O1 Output Frequency–0.0 Hz O2 Freq Reference–0.0 Hz ..Note: Enter Key — Holding the “Enter” key for more than 3 seconds will allow you to go directly to the programming mode. SVX9000 Drives MN04003009E—November 2011 www.eaton.com...
  • Page 9 To exit the Operate Menu to access the other menus, depress the ENTER button for 2 seconds. While in the other menus, if there is no keypad activity, the display will return to the Operate Menu after 30 seconds. SVX9000 Drives MN04003009E—November 2011 www.eaton.com...
  • Page 10 P1.1.17 Preset 0.00 Par. 10.00 105 Speeds preset by speed 1 1.1.2 operator. P1.1.18 Preset 0.00 Par. 40.00 speed 2 1.1.2 Parameter value can only be changed after the drive has been stopped. SVX9000 Drives MN04003009E—November 2011 www.eaton.com...
  • Page 11 (0 – U nMotor 8 = DC-Bus volt (0 – 1000V) P1.3.3 Analog 0.00 10.00 1.00 308 0 = No filtering output filter time Parameter value can only be changed after the drive has been stopped. SVX9000 Drives MN04003009E—November 2011 www.eaton.com...
  • Page 12 1 = Inverted P1.3.16 Analog output 475 0 = 0 mA 2 minimum 1 = 4 mA P1.3.17 Analog output 1000 2 scaling Parameter value can only be changed after the drive has been stopped. SVX9000 Drives MN04003009E—November 2011 www.eaton.com...
  • Page 13 Skip frequency 0.00 Par. 0.00 range 1 low 1.5.2 limit P1.5.2 Skip frequency 0.00 Par. 510 0 = Skip frequency range 1 high 1.1.2 range 1 not limit used P1.5.3 Skip frequency 10.0 acc./dec. ramp SVX9000 Drives MN04003009E—November 2011 www.eaton.com...
  • Page 14 700 0 = No response reference 1 = Warning fault 2 = Warning+ Previous Freq. 3 = Wrng+ PresetFreq 1.7.2 4 = Fault.stop acc. to 1.4.7 5 = Fault.stop by coasting 6 = Fault, Restart SVX9000 Drives MN04003009E—November 2011 www.eaton.com...
  • Page 15 P1.7.22 Response to 733 See P1.7.21 fieldbus fault P1.7.23 Response to 734 See P1.7.21 slot fault P1.7.24 FB MCW Bit 15 771 0 = No action 1 = Fault low 2 = Fault high SVX9000 Drives MN04003009E—November 2011 www.eaton.com...
  • Page 16 Menus M3 to M6 provide information on the Active Faults, Fault History, System Menu settings and the Expander Board setup. These menu items are explained in detail in Chapter 5 of the SVX9000 User Manual. SVX9000 Drives MN04003009E—November 2011 www.eaton.com...
  • Page 17 Brake chopper Control unit Slot fault supervision SVX9000 Device change PT100 board undertemperature temperature fault (same type) SVX9000 Device added — — overtemperature (same type) Motor stalled Device removed — — SVX9000 Drives MN04003009E—November 2011 www.eaton.com...
  • Page 18 Monitored Menu Items shown in the table above. Use the right arrow key to select the item to be modified and then the up or down arrow keys to select the new item. Press the ENTER key to accept the change. SVX9000 Drives MN04003009E—November 2011 www.eaton.com...
  • Page 20 Our focus is on delivering the right solution for the application. But, decision makers demand more than just innovative products. They turn to Eaton for an unwavering commitment to personal support that makes customer success a top priority. For more information, visit www.eaton.com/electrical.