Technical Menu - Access And Navigation - NTI FTVN085 Installation Start-Up Maintenance

Residential condensing gas boiler
Hide thumbs Also See for FTVN085:
Table of Contents

Advertisement

P. Technical Menu - Access and Navigation
To access advanced setup and troubleshooting parameters, it is
necessary to enter the Technical Menu. The Technical Menu includes a
number of Quick Access Menus which allow easy access to commonly
used parameters. See Q. Technical Menu - Menu Structure.
The Quick Access Menu option, "MENU", provides access to all
parameters. See R. Technical Menu - Complete Menu.
Instructions on how to access and change the menus are provided
below.
The various parameters can be activated and changed using the
buttons shown below:
OK and ESC buttons together for 5 seconds to access the technical
menu. CH + and – buttons to scroll through the menus and adjust
settings. OK button to select parameters and save settings. ESC button
to exit menu level / parameter without saving.
Figure 72 - Access to the Technical Area
AUTO
Part 1 - General Safety Information
The menu and parameter numbers are shown on the display.
CAUTION! THE MENUS RESERVED FOR QUALIFIED TECHNICIANS MAY
ONLY BE ACCESSED AFTER ENTERING THE ACCESS CODE.
To access the Menus, open the cover and proceed as follows (in this
2.3.1)
example: Parameter
OK and ESC
1.
Simultaneously press the
buttons for 5 seconds.
222.
The display shows
AUTO
CODE
3. Press the OK button.
MENU.
The display shows
AUTO
MENU
5. Press the "+" button to select
.
menu 2
AUTO
MENU
7. Press the "+" button to select the
sub-menu 23.
AUTO
PAR
10. Press OK to access the parameter.
T
the current parameter
he display shows
value. In this example,
.
100
AUTO
PAR
After making changes, press the ESC button
screen is restored.
Part 9 - Controls
AUTO
CODE
2. Press the "+" button to select 234,
the service code.
AUTO
MENU
4. Press the OK button.T
he display shows
0.
menu
AUTO
MENU
6. Press the OK button t
o access the
. The display shows sub-menu 20.
menu
AUTO
MENU
9. Press
OK t
o access the sub-menu
. T
he display
231.
shows the parameter
AUTO
PAR
11. Press the "+" or "-" buttons to
select a new value.
In this example, 96.
12. Press OK
to save the change, or press
ESC button
the
to exit without saving.
In this example press OK.
until the normal display
65

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ftvn110Ftvn150Ftvn199Ftvn110cFtvn150cFtvn199c ... Show all

Table of Contents