Checking Combustion Parameters; Converting The Appliance From Natural Gas To Propane Operation - NTI FTVN085 Installation Start-Up Maintenance

Residential condensing gas boiler
Hide thumbs Also See for FTVN085:
Table of Contents

Advertisement

Part 11 - Start-Up
Part 1 - General Safety Information
Models
Inlet Gas Pressure Nominal (Inches WC)
Inlet Gas Pressure Min/Max (Inches WC)
Ignition Power
Maximum CH Power Adjustable (%)
Minimum Power (%)
Max Power (%)
Ø) mm
Gas Diaphragm (
Gas Input (MBH)
Table 32 - Table Summarizing Powers
C. Checking Combustion Parameters
Menu 2. - Boiler Parameters
Submenu 3. - Parameter 1 Maximum Heating Power Adjustment
Submenu 2. - Parameter 0 Ignition Power
Submenu 3. - Parameter 5 Heating Ignition Delay
Maximum Heating Power Adjustment 2.3.1
The maximum heating power can be adjusted to between the
maximum and minimum power allowed by the boiler.
The display shows the heating power value between 100% ("100" on
the display) and 0% ("0") of this interval.
To check the maximum heating power, access menu 2/sub menu 3/
parameter1 (231) - see page 60.
Check the value. If necessary, modify it as indicated in Table 32.
Checking Ignition Power 2.2.0
To check the Ignition power access menu 2/sub menu 2/parameter 0
(220) - see page 60.
If necessary, modify it as indicated in Table 32.
Heating Ignition Delay Adjustment 2.3.5
This parameter is used to manually (0) or automatically (1) set the
heating ignition delay time. This is the time the boiler delays igniting
the burner after it has met the central heating mode setpoint and
switched off.
To change this parameter, access menu 2/sub menu 3/parameter 5
(2.3.5)- see page 60.
After selecting manual, access the successive parameter 2.3.6 to set
the delay between 0 and 7 minutes.
Automatic selection means that the boiler will establish the delay time
based on the set-point temperature.
D. Converting the Appliance from Natural Gas to Propane
Operation
NTI boilers are factory set to operate on Natural Gas. BEFORE
OPERATING ON PROPANE the boiler must be converted to Propane
using the included conversion kit specific to the boiler model.
WARNING
These instructions CANNOT be used to convert NTI appliance
models not referenced within these instructions. Contact NTI for
the availability of conversion kits and instructions for other models.
Failure to apply these instructions properly may result in
dangerous Carbon Monoxide levels, fire, or explosion, leading to
property damage, serious personal injury, or death.
80
FTVN085
Parameter
Natural
7
3.5 - 10.5
220
40
231
100
233
7
232 & 234
78
none
Max
85
Min
8.5
FTVN110 / 110C
Propane
Natural
Propane
11
7
11
8 - 13
3.5 - 10.5
8 - 13
28
100
11
100
6.4
none
6.4
110
11
LIQUEFIED PETROLEUM (LP) PROPANE
Liquefied Petroleum (LP) propane gas is heavier than air; therefore,
it is imperative that your boiler is not installed in a pit or similar
location that will permit heavier than air gas to collect.
Local Codes may require appliances fueled with LP gas be provided
with an alarm or an approved means of removing unburned gases
from the room. Check your local codes for this requirement.
FTVN
FTVN
NATURAL GAS TO PROPANE GAS
NATURAL GAS TO PROPANE GAS
CONVERSION INSTRUCTIONS
CONVERSION INSTRUCTIONS
Applicable Models:
FTVN085, FTVN110, FTVN150, FTVN199,
FTVN110C, FTVN150C, and FTVN199C
WARNING
This conversion kit shall be installed by a qualified
service agency in accordance with the manufacturer's
instructions and all applicable codes and requirements
of the authority having jurisdiction. If the information
in these instructions is not followed exactly, a fire,
an explosion or production of carbon monoxide
may result causing property damage, personal
injury or loss of life. The qualified service agency is
responsible for the proper installation of this kit. THE
INSTALLATION IS NOT PROPER AND COMPLETE UNTIL
THE OPERATION OF THE CONVERTED APPLIANCE IS
CHECKED AS SPECIFIED IN THE MANUFACTURER'S
INSTRUCTIONS SUPPLIED WITH THE KIT, WHICH
NECESSITATES THE USE OF A CALIBRATED CO 2 /O 2
AND CO COMBUSTION ANALYZER.
FTVN150 / 150C
FTVN199 / 199C
Natural
Propane
Natural
7
11
7
3.5 - 10.5
8 - 13
3.5 - 10.5
35
100
6
4
91
91
8.5
6.4
none
150
15
ATTENTION:
Figure 80 - Conversion Kit
Instruction Cover
Propane
11
8 - 13
34
100
6
93
6.9
199
19.9

Hide quick links: