Approximate Time / Temperature Relationships in Scalds
120
o
F
125
o
F
130
o
F
135
o
F
140
o
F
o
145
F
150
o
F
155
o
F
Table 25 - Time and Temperature Relationship in Scalds
E. User Menu
Press the MENU button to open the

user menu.

To navigate within the menu or
parameters, press the + and - buttons (
or
).
To change a parameter, select it by
pressing the OK button.
To change the set value, press the +
and - buttons (
or
).
Press the OK button to save.
To exit without saving the changes,
press the ESC button.
Figure 64 - Access user menu
For parameters 4 to 11 in Table 26,
it is also possible to adjust the same
parameters for Zones 2 and 3, if
applicable.
NOTE: Zone 3 is only applicable
when using an optional NTI zone
controller.
By pressing the HISTORY button after
accessing
the parameter, the number
1 or 2 of the selected zone appears
next to the heating symbol:
.
Continue to change the setting as
described above.
More than 5 minutes
1 1/2 to 2 minutes
About 30 seconds
About 10 seconds
Less than 5 seconds
Less than 3 seconds
About 1 1/2 seconds
About 1 second
Activate change by pressing the OK button. + / - buttons scroll through and change values. Press OK button to
confirm a change. Press ESC to return without change.
1.
I-NET
WIFI
AP
SN
RESET
ITIME
ITEMP
2.
Date and Time (Only visible when ITIME is set to OFF)
The following values are displayed in a sequence.
Day (1-31)
Month (1-12)
Year (year)
Time (hh: mm) (*)
3.
DHW Comfort Function (Only applicable with Combi models)
OFF
ON
4.
Automatic C.H. temperature control / AUTO function
OFF
ON
5.
Room temperature Day
6.
Room temperature Night
7.
Time programs – heating schedule
0+24 h
P1
P2
P3
06-22 h
P EXT
8.
Outdoor Reset Curve Slope (only with AUTO function active)
9.
Outdoor Reset Curve Parallel Shift (only with AUTO function active)
Setting range + -7 at low temperature and + -14 at high temperature range (each step + or - 1.8°C)
10.
Automatic summer / winter changeover
/
ON
OFF
11.
Summer / winter changeover temperature
Table 26 - User Menu
WARNING
Indirect Water Heater Applications - Install an ASSE 1017 or ASSE 1070
temperature limiting or mixing valve to reduce the risk of scalding.
NOTE: Mixing valves do not eliminate the risk of scalding.
To avoid scalding:
Set the water heater set point temperature as low as possible.
Feel water before bathing or showering.
If thermostatic valves are required, use devices specifically
designed for such purpose. Install these devices in accordance
with instructions provided by the manufacturer.
Failure to install a temperature limiting or mixing valve and follow
these instructions could result in property damage, severe personal
injury, or death due to scalds.
ON/OFF Wi-Fi
Access point open for 10 minutes
Shows Wi-Fi (Not Appliance) serial number
Delete Wi-Fi settings and Disconnect user account
ON/OFF - Date and time set via the Internet.
Use Internet weather (only without outdoor sensor)
DHW Comfort function deactivated
DHW Comfort function Active
AUTO function deactivated
AUTO function Active (AUTO appears on the display)
/
only applicable if using NTI room sensor(s)
/
only applicable if using NTI room sensor(s)
/
only applicable if using NTI room sensor(s)
Always active
Family program
Program no lunch
Program with lunch
C.H. active from 06:00 to 22:00
Time program defined by REMOCON room unit or NTI NET app.
Active
Function deactivated
Part 9 - Controls
/
/
/
/
59