Info Menu; Date And Time (If Itime Is Set To Off) - NTI FTVN085 Installation Start-Up Maintenance

Residential condensing gas boiler
Hide thumbs Also See for FTVN085:
Table of Contents

Advertisement

Part 9 - Controls
F. INFO Menu
Press the MENU button for 5 seconds to access the INFO menu, navigate
within the INFO menu with + and - (both possible,
Figure 65 - Access Info menu

Info Menu

Parameter
01.
8.5.7
06.
8.3.1
07.
8.3.2
08.
8.3.3 / 8.4.0
09.
8.3.5
10.
8.3.4
11.
8.7.8
12.
4.3.0/5.3.0
13.
8.2.5
18.
8.2.2
20.
8.7.9
Table 27 - Info menu
G . Date and Time (If ITIME is set to OFF)
The control unit is equipped with a 365-day clock that displays
the day, month, year and time.
In order to ensure correct operation of the boiler when using
time programs, the date and time must be set correctly. If the
boiler is connected to the Wifi application, the Internet time is
automatically taken into account. Manual entry:
Day (1-31)
Months (1-12)
Year (2019)
Time (00:00)
/
Buttons
for the hour setting
/
Buttons
for setting minutes
60
or
).
Floor drying remaining days (with Floor Drying function active)
Room temperature [°F] (only with NTI Room Sensor connected) (Zone 1/2)
(item 2 - Figure 60)
(item 8 - Figure 60)
Attention: No values can be changed here, only information can
be read! Changes can only be made in the user menu or in the
specialist area.
Description
Supply water temperature [°F]
Return water temperature [°F]
DHW outlet or storage temperature [°F]
Outdoor temperature [°F]
Exhaust flue temperature [°F]
Burner power level [%]
DHW flow rate [gpm] (Combi Models only)
Actual fan speed [RPM/10]
Burner flame signal

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ftvn110Ftvn150Ftvn199Ftvn110cFtvn150cFtvn199c ... Show all

Table of Contents