Signs and symbols used ..................6 Structure of warnings ..................6 Components and tools ��������������������������������������������������������������������������������7 System components and tools ................7 VOGT Hammer / TurboSpade ................8 VOGT Soil Aerator / Air Injector................10 Identifying your device ..................11 General safety instructions ���������������������������������������������������������������������12 Basic principles ....................12 Intended use ......................12 Foreseeable misuse ...................12...
Page 4
12.4 Spare parts list Rammer ...................47 12.5 Spare parts Operating manual / Transport case ...........47 12.6 Spare parts list VOGT Soil Aerator ..............48 12.7 Spare parts list VOGT Air Injector ..............49 12.8 Spare parts list Injection unit ................50 Assembly Instructions ������������������������������������������������������������������������������51 13.1...
Countermeasures (action to prevent the hazard) Nature of hazard Consequences of hazard ¾ Countermeasures Subject to change without notice VH / VTS / VBL / VAI Translation of the original operating manual US edition 2021/01 Contact: +49(0)92 78-774 33-0 +49(0)92 78-774 33-11 www.vogt-tec.com...
Components and tools Components and tools 2�1 System components and tools Although each VOGT compressed air device is designed for specific types of task, all devices have the same general structure. Each compressed air device is made up of four components: ...
It is fitted with a vibration damping system to reduce the vibration load during work. VH 25 / VH 25 Delta: This device is the same as a VH 30 / VH 30 Delta but without the vibration damping system.
Page 9
Control elements 1. Trigger lever The trigger lever is used to start up the VOGT Hammer. The rammer is supplied with compressed air while the trigger lever is pressed down. VOGT TurboSpade With a low blow frequency but a high blow force and a sturdy 18 mm chis- el holder, the VOGT TurboSpade is ideal for vertical work.
Control elements 1. Trigger lever The trigger lever on the VOGT Soil Aerator is used to insert the injection tube into the material to be loosened (e.g. the soil). The rammer is sup- plied with compressed air while the trigger lever is pressed down.
Control elements 1. Trigger lever The trigger lever on the VOGT Soil Aerator is used to insert the injection tube into the material to be loosened (e.g. the soil). The rammer is sup- plied with compressed air while the trigger lever is pressed down.
3�2 Intended use VOGT Hammer / TurboSpade VOGT Hammers / TurboSpades are hand-held devices (machinery) for performing mechanical tasks such as compacting, ramming, scraping, cut- ting, breaking up, removing, solidifying, uncovering, cleaning, digging, and loosening materials or aeration. They must be used together with original VOGT tools and accessories.
The rammer on a VOGT compressed air device must never be held under water. This may cause damage to the device or even render it unusable.
Page 14
< 10° Always use a VOGT compressed air device that is appropriate for the various tasks to be performed in order to prevent excessive strain on your body. Suitable device versions and sets are available for different tasks.
The hose clamp prevents the end of the hose from lashing out if the coupling is unintentionally released under pressure. Always bring the stop cock on the VOGT Soil Aerator and the VOGT Air Injector back into its locked position after aerating the material to be loos- ened in order to prevent compressed air from flowing out uncontrollably.
If any dust or fumes are released, the top priority is to monitor them where they are released. A dust suction (Z 800) is available as an optional accessory for VOGT Hammers / TurboSpades. The VOGT Hammer / TurboSpade must be operated and maintained as ...
Page 17
Make sure that any component or workpiece to be worked is fixed securely in place. Place the VOGT Hammer / TurboSpade securely on the surface to be worked before switching the device on. Always wear impact-resistant eye protection. The degree of protection ...
They must be trained and authorized to maintain these compressed air devices safely. Subject to change without notice VH / VTS / VBL / VAI Translation of the original operating manual US edition 2021/01 Contact: +49(0)92 78-774 33-0 +49(0)92 78-774 33-11 www.vogt-tec.com...
Wear foot protection Sound power level in accordance with Directive 2000/14/EC (Outdoor Directive) Subject to change without notice US edition 2021/01 VH / VTS / VBL / VAI Translation of the original operating manual Contact: +49(0)92 78-774 33-0 +49(0)92 78-774 33-11 www.vogt-tec.com...
Transportation The VOGT compressed air devices are carried to where they are to be used. It is advisable to use the VOGT transport case available as an acces- sory or a similar transportation aid for this purpose. The transport case has space for the compressed air device, the most important accessories, the operating manual, and other documents if required.
Getting ready for operation Getting ready for operation Before you can use your VOGT compressed air device, it must be fitted with a tool appropriate for the task and connected to a suitable com- pressed air supply. 5�1 Inserting and removing tools The various tools available for the VOGT compressed air devices allow them to be used flexibly.
VTS to fix the clips in place. Subject to change without notice VH / VTS / VBL / VAI Translation of the original operating manual US edition 2021/01 Contact: +49(0)92 78-774 33-0 +49(0)92 78-774 33-11 www.vogt-tec.com...
An effective feed rate of at least: − 190 l/min. for the following models: VH 25 / VH 25 Delta / VH 30 / VH 30 Delta − 255 l/min for the following models: VH 50 / VH 50 Delta / VH 50.18 / VH50.18 Delta / VH 60 / VH 60 Delta / VH 60.18 / VH 60.18 Delta /...
Page 24
3. Check that the hoses and couplings are leak-tight. If they are not, switch off the compressed air supply and replace the hose immediate- 4. Connect the compressed air hose to the connecting hose on the VOGT compressed air device. The VOGT Hammer / TurboSpade may start up unintentionally�...
Page 25
Getting ready for operation Recommended operating pressure, VOGT Hammer Task / Material Value / Unit Renovating joints 3.0 to 5.0 bar (44 to 72 psi) Floor coverings, coatings 4.0 to 6.0 bar (58 to 87 psi) Parquet, laminate 5.0 to 6.0 bar (72 to 87 psi) Thin plaster, textured plaster 5.0 bar (72 psi)
An effective feed rate of at least 2,500 l/min. Connecting the compressed air supply Follow these steps to connect your VOGT compressed air device to the compressed air supply: 1. Secure the connecting coupling using a hose connection protection (I91 011).
Always hold the VOGT compressed air device in both hands when working with it: With the VOGT Hammer, put one hand on the stick or the optional handle (Z 625 and Z 650 respectively) and the other on the handle.
Page 28
Check whether the tool holder is covered with a film of oil. If not, drop a few drops of VOGT Special Oil Z 500 into the connecting hose and op- erate the compressed air device without a tool for about ten seconds.
Page 29
7. Close the stop cock on the control valve. 8. Pull the VOGT Soil Aerator out again. If the injection tube gets stuck, it can be freed with a few blows from the rammer. If this does not work, use the shaft extractor for Injection- or Aeration tube (I91 006).
Page 30
After no more than four hours of operating the device, check whether the tool holder is covered with a film of oil. If not, drop a few drops of VOGT Special Oil Z 500 into the connecting hose. We would always recommend operating the device together with the VOGT precision in-line oiler Z 300.
Page 31
4. If necessary, readjust the quantity of oil on the in-line oiler. Oil types Please use VOGT Special Oil (Z 500) or a resin-free pneumatic oil when working in standard conditions. On request, VOGT can supply the following oils for non-standard condi- tions of use: ...
For this reason, always fix faults as soon as you discover them or contact VOGT Customer Service. Cleaning Clean the VOGT compressed air device, the tools, the hose, and other accessories with a clean dry or oiled cloth. ...
Faults of any kind must be fixed immediately to prevent major damage to the VOGT compressed air device. If a fault occurs, disconnect the VOGT compressed air device from the compressed air supply straight away. Check once again that the device is depressurized before troubleshooting the fault.
Page 34
Subject to change without notice VH / VTS / VBL / VAI Translation of the original operating manual US edition 2021/01 Contact: +49(0)92 78-774 33-0 +49(0)92 78-774 33-11 www.vogt-tec.com...
It must be returned to the manufacturer or sent for recycling if possible. Subject to change without notice US edition 2021/01 VH / VTS / VBL / VAI Translation of the original operating manual Contact: +49(0)92 78-774 33-0 +49(0)92 78-774 33-11 www.vogt-tec.com...
Numerous special lengths are also available on request. Technical data VOGT Hammer VH 25 / VH 30 Type VH 25-70 VH 30-70 VH 25-90 VH 30-90 VH 25-110 VH 30-110 VH 25-130 VH 30-130 Total Length 70 cm 70 cm...
Page 38
Technical data Technical Data VOGT TurboSpade VTS 50 / VTS 60 VTS 50-50 VTS 60-50 VTS 50-65 VTS 60-65 VTS 50-80 VTS 60-80 VTS 50-120 VTS 60-120 Total Length 50 cm 50 cm 65 cm 65 cm 80 cm 80 cm...
Page 39
Technical data Technical Data VOGT Soil Aerator Designation Value / Unit Operating medium Operating pressure 3,0 to 10,0 bar (43 - 145 psi) Air consumption 2.500 l/min (88,3 cfm) at 6.0 bar (87 psi) Tool holder 18 mm hexagon Inner hose diameter min.
Bio-Oil (834 010) for work in food processing companies or comparable environments. You can find safety data sheets for the VOGT oils offered on the VOGT website in the download area. Subject to change without notice VH / VTS / VBL / VAI Translation of the original operating manual...
(delivery note/date). The product is deemed to have been put into use on the day on which VOGT Baugeräte GmbH or an authorised distribution partner handed the product over to the purchaser unless a written agreement to the contrary has been made.
Page 42
VOGT Baugeräte GmbH. Products that have been repaired during the warranty period by − people who are not employees of VOGT Baugeräte GmbH or their authorised service centres. − Costs for other possible damage or loss, whether this occurs directly, indirectly, unintentionally, specifically or consequently, which results from the use or lack of a possibility to use the product.
Product VOGT Pneumatic Hammer / TurboSpade / Soil Aerator and Air Injector Type VH 25, 30, 50, 60, 50.18, 60.18 _ .D / VTS 50, VTS 60 / VBL / VAI Serial number From 101 in each case Project number...
T-handles and Delta-handles Plug with O-Ring 160 012 150 070 Fastening screw Subject to change without notice US edition 2021/01 VH / VTS / VBL / VAI Translation of the original operating manual Contact: +49(0)92 78-774 33-0 +49(0)92 78-774 33-11 www.vogt-tec.com...
Spare parts 12�7 Spare parts list VOGT Air Injector Air Injector Air Injector Pos� Description Art�-Nr� AI7 000 Remote control complete (Pos. 2, 3, 5 - 7, 2x9) I30 005 Ball valve with wing grip I40 016 Claw coupling black 3/4"...
170 cm I10 170 I15 170 200 cm I10 200 I15 200 Subject to change without notice VH / VTS / VBL / VAI Translation of the original operating manual US edition 2021/01 Contact: +49(0)92 78-774 33-0 +49(0)92 78-774 33-11 www.vogt-tec.com...
YouTube Manual: Mounting Scraper holder Subject to change without notice US edition 2021/01 VH / VTS / VBL / VAI Translation of the original operating manual Contact: +49(0)92 78-774 33-0 +49(0)92 78-774 33-11 www.vogt-tec.com...
(10mm) and Allen cross blade holder. key (4mm). Subject to change without notice VH / VTS / VBL / VAI Translation of the original operating manual US edition 2021/01 Contact: +49(0)92 78-774 33-0 +49(0)92 78-774 33-11 www.vogt-tec.com...
Subject to change without notice US edition 2021/01 VH / VTS / VBL / VAI Translation of the original operating manual Contact: +49(0)92 78-774 33-0 +49(0)92 78-774 33-11 www.vogt-tec.com...
1. Insert the cone holder into the chisel holder. 2. Insert the cone holder into the chisel receiver. 3. Align the cone position with the T-handle 4. Put the VOGT compressed air equipment into ope- ration (see Sections 3 and 4). 5. Let the equipment run briefly, the cone holder will...
You can find our complete overview of tools, compressors and accessories in our product catalog or at www.vogt-tec.de Subject to change without notice US edition 2021/01 VH / VTS / VBL / VAI Translation of the original operating manual...
Page 56
This operating manual is available in various other languages from the media library. Bayreuth We are reachable for you: Monday - Thursday 07:30 - 17:00 Friday 07:30 - 15:00 VOGT Baugeräte GmbH Industriestraße 39 D-95466 Weidenberg +49(0)92 78-774 33-0 +49(0)92 78-774 33-11 info@vogt-tec.de www.vogt-tec.de facebook.com/vogtbaugeraete...