Specification - Chroma 69225 Series User Manual

Regenerative charge/discharge tester
Table of Contents

Advertisement

1.3

Specification

The operation specifications of 69225/69212 series are shown as Table 1-2. All specifications
are tested following Chroma standard test procedure. Test condition is 25 ± 5°C and under
the condition of resistance load.
Model
Channel
Voltage Range
Maximum Current
Max Power
CC Mode Accuracy
Current Resolution
CV Mode Accuracy
Voltage Resolution
CP Mode Accuracy
Power Resolution
Voltage Range *
Maximum Current
Max Power
CC Mode Accuracy
Current Resolution
CV Mode Accuracy
Voltage Resolution
CP Mode Accuracy
Power Resolution
Voltage Range
Voltage Accuracy
Voltage Resolution
Current Range
Current Accuracy
Current Resolution
Power Range
Power Accuracy
Power Resolution
Temperature Range
Temperature Accuracy
Temperature Resolution
Table 1-2
69225-100-4
4
Charge Mode
0-100Vdc
50A
2.5KW
0.1%stg.+ 0.05%F.S.
5mA
0.1% stg.+ 0.05% F.S.
3mV
0.2% stg.+ 0.1% F.S.
0.5W
Discharge Mode
0-100Vdc
50A
2.5KW
0.1% stg.+ 0.05% F.S.
5mA
0.1% stg.+ 0.05% F.S.
3mV
0.2% stg.+ 0.1% F.S.
0.5W
Measurement
0-100Vdc
0.02% rdg.+ 0.02% F.S.
3mV
20A/50A
0.05% rdg.+ 0.05% rng.
2mA
2500W
0.07% rdg.+ 0.07% F.S.
0.2W
0-90°C
±2°C
0.1°C
Overview
69225-60-4
4
0-60Vdc
62.5A
2.5KW
0.1% stg.+ 0.05% F.S.
5mA
0.1% stg.+ 0.05% F.S.
2mV
0.2% stg.+ 0.1% F.S.
0.3W
0-60Vdc
62.5A
2.5KW
0.1% stg.+ 0.05% F.S.
5mA
0.1% stg.+ 0.05% F.S.
2mV
0.2% stg.+ 0.1% F.S.
0.3W
0-60Vdc
0.02% rdg.+ 0.02% F.S.
2mV
24A/62.5A
0.05% rdg.+ 0.05% rng.
5mA
2500W
0.07% rdg.+ 0.07% F.S.
0.3W
0-90°C
±2°C
0.1°C
1-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

69212 series69225-100-469225-60-469212-60-469212-20-4