Electrical Equipment; Cleaning And Blowing Out The Electrical Components; Checking The Battery Acid Level And Electrolyte Density - Still FXV 14 N Original Instructions Manual

Pallet stacker
Hide thumbs Also See for FXV 14 N:
Table of Contents

Advertisement

5

Electrical equipment

Electrical equipment
Cleaning and blowing out the elec-
trical components
CAUTION
Electrical hazards
Always disconnect the battery connector before
working on an electrical component.
– Press in the emergency off switch.
– Disconnect the battery connector.
– Open the technical compartment hood.
– Blow the electrical components with com-
pressed air.
WARNING
Use of compressed air
It is advisable to wear protection goggles and a
mask.
– Check the condition of the cable harness
connector pins.
Checking the battery acid level and
electrolyte density
NOTE
Remove the battery from its compartment to
check the water level.