Download Print this page
Securam ProLogic L22 Operating Instructions Manual

Securam ProLogic L22 Operating Instructions Manual

Hide thumbs Also See for ProLogic L22:

Advertisement

Quick Links

ProLogic L22
ProLogic L22 Operation Instructions
Document No: EC-0601A-L22-130919
Version No: V1.01
1.0 System Installation
1.1 System Components
1.2 Pairing the EntryPad with the Lock(s)
1.3 Lock and EntryPad Installation
1.4 Installing Battery
1.5 Test Lock Operation
2.0 Lock Operation
2.1 Opening the Lock
2.2 Opening the Lock in Time Delay
2.3 Opening the Lock Under Duress
2.4 Opening the Lock in Dual Control
2.5 Opening the Lock with a Multi-Lock System
3.0 Set Date and Time
3.1 Set Clock Time
3.2 Show Clock Time
3.3 DayLight Savings Time
4.0 Code Management
4.1 Enrolling New users
4.2 Change Code
4.3 Delete One User
4.4 Delete All Users
4.5 Disable/Enable User
5.0 System Identification
5.1 System Info
Operation Instructions
6.0 Time Delay
6.1 Set/Cancel Time Delay
6.2 Set Duress Time Delay
6.3 Setting Time Delay Override Users
7.0 Audit Trail Functionality
7.1 Show Audit Trail
7.2 Uploading Audit Trail
8.0 Single or Dual Control
8.1 Enable Dual Mode
9.0 Door Management
9.1 Max. Door Open Time
9.2 Configuring a Multi-lock system
9.3 Set Number of Locks
9.4 Authorize Locks
9.5 Enable Sequence
10.0 Duress Management
10.1 Duress Setup and Wiring Configuration
10.2 Duress Code Shift
11.0 Device Management
11.1 Set Device ID
12.0 Data Management
12.1 Encryption Key Set
13.0 Recovering the System – Reset to Default
13.1 Recovery Code Set
13.2 Recover System
13.3 Simple Mechanical Reset
14.0 System Testing
14.1 Cycle Testing
14.2 Hardware Testing
15.0 Menus
15.1 The ProLogic L22 Menus
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the ProLogic L22 and is the answer not in the manual?

Questions and answers

Summary of Contents for Securam ProLogic L22

  • Page 1 4.1 Enrolling New users 4.2 Change Code 14.0 System Testing 4.3 Delete One User 14.1 Cycle Testing 4.4 Delete All Users 14.2 Hardware Testing 4.5 Disable/Enable User 15.0 Menus 5.0 System Identification 15.1 The ProLogic L22 Menus 5.1 System Info...
  • Page 2 SECURAM safe lock systems can operate in two different modes depending upon the type of EntryPad being used with the lock body. The ProLogic L22 is a digital lock system and therefore the lock must also be programmed in digital mode. Both modes follow the same steps to reset / set which is done by following the steps detailed below: Step 1: Ensure the battery is disconnected from the Entry Pad.
  • Page 3 “Fail to Link with Lock”, repeat the reset procedure. Be sure to hold down the reset button through steps 5-8. If you have difficulty resetting the lock, please call SECURAM Tech Support at (805) 988-8088 or email info@securamsys.com.
  • Page 4 Operation Instructions  Be careful not to crimp or damage the lock cable upon EntryPad installation. 1.5 Testing the Lock Operation The ProLogic L22 comes with two factory default codes: Super Code (ID00) is 111111 • • Manager Code (ID01) is 123456 Enter one of the valid codes to verify that the communication between the lock and EntryPad.
  • Page 5 ProLogic L22 Operation Instructions The display will read: ID00 The lock will relock after 6 seconds. Note: Time to relock is hard coded and cannot be changed. 2.2 Opening Lock with Time Delay Programmed When Time Delay has been programmed, the user must enter a valid code.
  • Page 6 Operation Instructions The ProLogic L22 has a Duress Feature, which allows a User or Admin to open the lock and send a silent Duress signal indicating that you are in danger. By default, the duress function is active and cannot be disabled.
  • Page 7 Step 2: The system will now prompt you to enter the number of the Lock to open 3.0 Set Date and Time The ProLogic L22 is an audit lock and it tracks events based on user, activity, date, and time. In order to set the system date and time complete the following process.
  • Page 8 Step 5: The LCD will display the current system date and time, as follows: 3.3 DayLight Savings Time The ProLogic L22 can be set to manage Daylight Savings Time and automatically updating preset date and time. Using this menu selection, you can turn on Daylight Savings Time management or turn it off.
  • Page 9 ProLogic L22 Operation Instructions Step 6: (Starting Month) The system will now request the month in which Daylight Savings Time is to begin. The default is North American DST Month 3 – March. To change press the  and ...
  • Page 10 Therefore to set to the North American DST, just select “Y” on the first display screen and then accept the defaults for all other settings by pressing OK. 4.0 Code Management The ProLogic L22 comes with two default codes: Super Code (ID00) is 111111 •...
  • Page 11 ProLogic L22 Operation Instructions The new code is now enrolled and available to be used to open the lock 4.2 Change Code Step1: Press the Menu/OK button Step 2: Using the  and , scroll to the System Menu and Press Menu/OK Step 3: The display will prompt you to enter a valid code.
  • Page 12 ProLogic L22 Operation Instructions The “Select Menu” message will be displayed as follows: Step 4: Scroll UP to the menu selection “Delete One User” and Press OK Step 5: Press OK Step 6: The system will ask which User Code is to be deleted. Press  and  until the desired USER ID is reached.
  • Page 13 ProLogic L22 Operation Instructions The only remaining code will be the default code as follows: • Manager Code (ID01) is 123456 4.5 Disable/Enable User Codes This feature would be used in order to disable a user code as opposed to deleting it. Disable/Enable user codes options may be used when a user’s access rights are temporarily revoked.
  • Page 14 This menu feature would be used to determine the type of safe lock system being used. Many of the SECURAM ProLogic EntryPads look the same, but the features sets and capabilities vary greatly depending upon the software being utilized. To determine the type of ProLogic Safe Lock system, follow this process: 5.1 System Info:...
  • Page 15 ProLogic L22 Operation Instructions Step 6: The system will now display the Time Window. This is the preset length of time allowed to enter a valid code after Time Delay has expired. Press the  and  to select the Time Window value desired.
  • Page 16 When TDO is set to ID00, only ID00 and ID01 have TDO authority. By default, ID02 is selected as TDO. 7.0 Audit Trail Functionality The ProLogic L22 records 200 date and time stamped audit trail events. It stores the most recent 200 events and overwrites the oldest first. The Audit Trail can be viewed on the LCD screen only.
  • Page 17  and . 8.0 Single or Dual Control The ProLogic L22 has the ability to operate in either Single Control mode or Dual Control Mode:  Single Control Mode: One valid code will open the safe lock system.
  • Page 18 9.2 Configuring a Multi-Lock system The ProLogic L22 is capable of managing 4 locks. A CB11-1T4 is required to operate 4 locks with the ProLogic L22 EntryPad. In order to manage more than one lock, you need to tell the system how many locks are connected, and then identify the locks with a number.
  • Page 19 ProLogic L22 Operation Instructions Step 3: The display will prompt you to enter a valid code. Enter either the Super Code (ID00) or the Manager Code (ID01). The “Select Menu” message will be displayed as follows: Step 4: Scroll  to the menu selection “Set Number of Locks” and Press OK.
  • Page 20 ProLogic L22 Operation Instructions Step 5: Now select the range of User IDs to have access to these locks. The system will display programmed users. First select the beginning of the range “From USER ID XX”. Use the  and  buttons to navigate to the desired User ID.
  • Page 21 10 seconds later the selected inner compartment lock will open. 10.0 Duress Management The ProLogic L22 offers Duress functionality. In the event of a burglary, or specifically a “hold up” at your place of business where the culprit demands entrance to the safe, Users can provide entrance to the safe.
  • Page 22 ProLogic L22 Operation Instructions Step 4: Scroll  to the menu selection “Duress Code Shift” and Press OK. Step 5: Using the numbers on the EntryPad enter the desired Duress Shift (1-99); and press OK. All Users will now enter their code +/- the Duress Shift value. For example, if you set the Duress...
  • Page 23 12.1 Encryption Key Set The ProLogic L22 sends and receives data to the lock in an encrypted form. This is a security measure to ensure that all data is protected. The Encryption Key is set during the manufacturing process with a default encryption key value.
  • Page 24 The alpha numeric code must be deciphered using SECURAM’s Authorization Code Generator Software. The alpha-numeric code is entered into the software together with the encryption code. Through the software, these codes are deciphered to generate a One Time Use Reset Code.
  • Page 25 Step 6: The LCD screen will display a key Code. Record this number and call an authorized SECURAM Recovery Center or SECURAM Tech Support at 1-805-988-8088 for an Authorization Code. (This code remains valid for a period of 20 minutes only).
  • Page 26 Time Delay, if programmed previously, remains active. 13.3 Simple Mechanical Reset SECURAM Safe Locks can operate in either Analog mode or Digital mode. When they are paired with the SafeLogic Series (EntryPads with no LCD screen or fingerprint reader) the safe lock operates in analog mode.
  • Page 27 The ProLogic L22 is a digital system and can be paired with any SECURAM safe lock body. If the lock body that you are pairing the ProLogic L22 with has been paired previously with an analog system, for example the SafeLogic Basic (or any other SafeLogic Series EntryPad)or was set at the factory...
  • Page 28 1) Cycle Testing 2)Hardware Testing This is a very unique feature to SECURAM safe lock systems. As the access system on a fortified steel box – the safe -- it is imperative that safe locks can provide solid performance. SECURAM offers this unique menu selection that allows you to test the lock system performance through actual Cycle Testing.
  • Page 29 15.0 Menus There are two menus on the ProLogic L22, the root menu and a sub-menu. The sub-menu is accessible by entering a valid code. The menu selections in the sub-menu change depending upon the level of the code entered.

This manual is also suitable for:

Ec-0601a-l22-c-ii-ch