Electromechanical redundant safe lock system (14 pages)
Summary of Contents for Securam ProLogic L02-C
Page 1
3.4 Delete One User 12.0 Menus 3.5 Delete All Users 12.1 The ProLogic L02-C Menus 3.6 Disable/Enable User IMPORTANT: It is imperative that all programming be completed with the safe door in its open position, such that the programmer can gain access to the lock...
Page 2
SpringBolt – Part #EL-0801 Note: The ProLogic L02-C can control up to 4 locks when used in conjunction with the Expansion Box – Part # CB11-1T4. (If setting up a multi-lock system, please refer to Section 10.2 – Multi-Lock Systems) 1.2 Pairing the EntryPad and the Lock...
Page 3
“Fail to Link with Lock”, repeat the reset procedure. Be sure to hold down the reset button through steps 5-7. If you have difficulty resetting the lock, please call SecuRam Tech Support at (805) 988-8088 or email info@securamsys.com.
Page 4
Put the battery compartment back into the EntryPad. Push the latch of the battery compartment up until it snaps closed. See Fig. 3 1.5 Testing the Lock Operation The ProLogic L02-C comes with two factory default codes: • Super Code (ID00) is 111111 •...
Page 5
ProLogic L02-C Operation Instructions 2.0 Lock Operation Upon initial power up, the LCD screen starts a communications test as shown below: Including Model Number Software Version Number No. of Users/ No. Users Programmed Lock ID#/Host ID# ...
Page 6
Step 5: Enter a valid Code to open the lock. 2.3 Opening the Lock in Dual Control The ProLogic L02-C can be programmed so that two User codes are required to open the lock. This function is called “Enable Dual Mode”, See 8.1...
Page 7
It is strongly recommended that both these default codes are changed before the lock system is put into service. The ProLogic L02-C has the capability to add up to 29 codes, in addition to the default codes. ID02 is a Manager Code and therefore has management functionality (the same as ID01).
Page 8
ProLogic L02-C Operation Instructions 3.1.1 PW L – 6; Users – 10 – This is the default mode. NOTE: This operation must be performed with the safe door open and with access to the back of the lock, as a mechanical reset must be performed during this programming sequence.
Page 9
ProLogic L02-C Operation Instructions Step1: Press the Menu/OK button. Step 2: Using the and , scroll to the System Menu and Press Menu/OK. Step 3: The display will prompt you to enter a valid code. Enter the Super Code (ID00) only .
Page 10
ProLogic L02-C Operation Instructions Step 3: The display will prompt you to enter a valid code. Enter the Super Code (ID00) only . This function is not available to Manager Codes ID01 or ID02. The “Select Menu” message will be displayed as follows: Step 4: Scroll ...
Page 11
ProLogic L02-C Operation Instructions Step 2: Using the and , scroll to the System Menu and Press Menu/OK Step 3: The display will prompt you to enter a valid Administrator code Enter either the Super Code (ID00) or the Manager Code (ID01). The “Select Menu” message will be displayed as follows: Step 4: Scroll ...
Page 12
ProLogic L02-C Operation Instructions Step 4: Scroll to the menu selection “Change Code” and Press OK Step 5: The display will show this message on the display “Set Code of IDXX” to be changed. Step 6: Enter the new 6 digit code.
Page 13
ProLogic L02-C Operation Instructions Step 7: Press OK. This User Code is now deleted from the system. 3.5 Delete All Users This feature is used to delete all users from the system. Upon executing this command, all users will be deleted and Manager Code will be reset as follows: ...
Page 14
ProLogic L02-C Operation Instructions After the code has been disabled, it can be re-enabled at a later time, following the same process by selecting “Enable User”. Step1: Press the Menu/OK button. Step 2: Using the and , scroll to the System Menu and Press Menu/OK.
Page 15
This menu feature would be used to determine the type of safe lock system being used. Many of the SecuRam ProLogic EntryPads look the same, but the features sets and capabilities vary greatly depending upon the software being utilized. To determine the type of ProLogic Safe Lock system, follow this process: 4.1 System Info:...
Page 16
ProLogic L02-C Operation Instructions 5.0 Time Delay Time Delay is a feature used to deter burglary. Provided a prospective burglar has knowledge that a Time Delay safe is in use, the likelihood of burglary is greatly reduced. Time Delay is a feature that requires the User to enter his/her code, wait a prescribed period of time, and then re-enter a valid code to unlock the safe lock.
Page 17
When TDO is set to ID00, only ID00 has TDO authority. 6.0 Single or Dual Control The ProLogic L02-C has the ability to operate in either Single Control mode or Dual Control Mode: Single Control Mode: One valid code will open the safe lock system.
Page 18
Disable Dual Mode. Therefore to Disable Dual Mode, follow the steps above. 6.2 Dual Mode Group ID The ProLogic L02-C has the ability to establish a management rule related to the Dual Mode function. This management rule is established in the menu selection “Dual Mode Group ID”. By enabling this function, the available User codes of the lock are divided into two groups: Group A would be “Dual...
Page 19
ProLogic L02-C Operation Instructions Step 5: Now using the and buttons, specify which User ID will define Group A and press OK. If you specify that this number is 00, the feature will be disabled and normal Dual Mode rules will apply –...
Page 20
ProLogic L02-C Operation Instructions Step 4: Scroll to the menu selection “Enable Manager” and Press OK. Manager Mode is now enabled. In this Mode: ID01 Code cannot open the safe and is used to toggle on/off all User codes. ID01 still has all its programming functions.
Page 21
Operation Instructions The ProLogic L02-C is capable of managing 4 locks. A CB11-1T4 is required to operate 4 locks with the ProLogic L02-C EntryPad. In order to manage more than one lock, you need to tell the system how many locks are connected, and then identify the locks with a number.
Page 22
ProLogic L02-C Operation Instructions Step 4: Scroll to the menu selection “Authorize Locks” and Press OK. Step 5: Now select the range of User IDs to have access to these locks. The system will display programmed users. First select the beginning of the range “From USER ID XX”.
Page 23
9.1 Encryption Key Set The ProLogic L02-C sends and receives data to the lock in an encrypted form. This is a security measure to ensure that all data is protected. The Encryption Key is set during the manufacturing process with a default encryption key value.
Page 24
The alpha numeric code must be deciphered using SecuRam’s Authorization Code Generator Software. The alpha-numeric code is entered into the software together with the encryption code. Through the software, these codes are deciphered to generate a One Time Use Reset Code.
Page 25
Step 6: The LCD screen will display a key Code. Record this number and call an authorized SecuRam Recovery Center or SecuRam Tech Support at 1-805-988-8088 for an Authorization Code. (This code remains valid for a period of 20 minutes only).
Page 26
Code. The default recovery Code is 999999. Step 4: The LCD screen will display an alpha-numeric number random key. Record this number and call an authorized SecuRam Recovery Center or SecuRam Tech Support at 1-805-988-8088. This code remains valid for a period of 20 minutes only.
Page 27
Note: The pairing of the StrikeBolt and the ProLogic L02-C EntryPad is not UL listed. If the lock body that you are pairing the ProLogic L02-C with has been paired previously with an analog system, for example the SafeLogic Basic (or any other SafeLogic Series EntryPad)or was set at the factory...
Page 28
The ProLogic L02-C has an onboard system test called “Cycle Testing” This is a very unique feature to Securam safe lock systems. As the access system on a fortified steel box – the safe -- it is imperative that safe locks can provide solid performance. SecuRam offers this unique menu selection that allows you to test the lock system performance through actual Cycle Testing.
Page 29
ProLogic L02-C Operation Instructions The system will now cycle the motor drive system, locking and unlocking the lock body every 1.5 seconds. The cycle testing will continue until the battery depletes itself of energy or power is removed.
Page 30
Operation Instructions 12.0 Menus There are two menus on the ProLogic L02-C, the root menu and a sub-menu. The sub-menu is accessible by entering a valid code. The menu selections in the sub-menu change depending upon the level of the code entered. Super Code (ID00), and Manager Codes (ID01 and 02) have access to the all programming menus.