IMPORTANT: The following charts are guides to select-
ing the pump that is compatible with the fluid you will be
pumping. These recommendations are based solely on
the materials of pump construction (refer to the Technical
Data on pages 31–35). It is the responsibility of the user
to follow the recommendations of the fluid manufacturer
and any local, state, and federal guidelines for safe han-
dling of a particular fluid. Read and follow all warnings re-
garding fluid use and compatibility given in this manual.
FLUID
Pump 220–617
(
PTFE
Acid
Inorganic
POOR
Organic
FAIR
Alcohols
EXCELLENT
Aldehydes
VERY GOOD
Aliphatics
EXCELLENT
Alkalies
POOR
Amines
VARIES
Animal Oils
EXCELLENT
Aromatics
EXCELLENT
Esters
Alkyl Phosphate
POOR
Aryl Phosphate
VARIES
Silicate
VARIES
Ethers
EXCELLENT
Halogenated Solvents
GOOD
Hydrocarbon Oils
EXCELLENT
Ketones
EXCELLENT
Silicone Oils
EXCELLENT
Water
EXCELLENT
POLYPROPYLENE PUMP MODELS 223–154 AND 223–155
FLUID
Pump 223–154
PTFE
(
Acid*
Inorganic
VERY GOOD
Organic
VERY GOOD
Alcohols
EXCELLENT
Aldehydes
FAIR
Aliphatics
FAIR
Alkalies
VERY GOOD
Amines
FAIR
Animal Oils
EXCELLENT
Aromatics
POOR
Esters
Alkyl Phosphate
VERY GOOD
Aryl Phosphate
VARIES
Ethers
POOR
Halogenated Solvents
POOR
Hydrocarbon Oils
FAIR
Ketones
FAIR
Silicone Oils
EXCELLENT
Water
EXCELLENT

FLUID COMPATIBILITY CHARTS

ACETAL PUMP MODELS 220–617 AND 220–618
Pump 220–618
(buna–N)
)
POOR
FAIR
VERY GOOD
POOR – FAIR
EXCELLENT
POOR
POOR
VARIES
VARIES
POOR
FAIR – POOR
VERY GOOD
POOR
FAIR – POOR
VERY GOOD
POOR
EXCELLENT
EXCELLENT
Pump 223–155
(buna–N)
)
POOR
FAIR
VERY GOOD
POOR – FAIR
FAIR
POOR
POOR
EXCELLENT
POOR
POOR
POOR
POOR
FAIR – POOR
FAIR
POOR
GOOD
EXCELLENT
CAUTION
Safe Operating Temperature
Minimum: 40 F (4.4 C); Maximum: 150 F (66 C)
These temperatures are based upon mechanical
stress only and may be significantly altered by
pumping certain chemicals. Consult engineering
guides for chemical compatibilities and temperature
limits, or contact Graco T
1–800–543–0339.
This chart is only a guide to selecting the pump and dia-
phragm material which is compatible with the fluid you
are pumping. Always read and follow the fluid supplier's
recommendations on material and fluid compatibility.
WARNING
To reduce the risk of serious bodily injury and prop-
erty damage from component rupture, always fol-
low these precautions:
1. Never use fluids in this pump which are not
compatible with the wetted parts listed in the
Technical Data on pages 31–35, or with the
diaphragm of this pump.
2. Read and follow all warnings regarding USING
HAZARDOUS FLUIDS and Fluid Compati-
bility on page 3.
This chart is only a guide to selecting the pump and dia-
phragm material which is compatible with the fluid you
are pumping. Always read and follow the fluid supplier's
recommendations on material and fluid compatibility.
*
Polypropylene is glass–filled and not suitable for
pumping hydrofluoric acid.
Contact with any acids or exposure to acid fumes will
damage the acetal and stainless steel non–wetted
parts of the polypropylene pumps.
WARNING
To reduce the risk of serious bodily injury and prop-
erty damage from component rupture, always fol-
low these precautions:
1. Never use fluids in this pump which are not
compatible with the wetted parts listed in the
Technical Data on pages 31–35, or with the
diaphragm of this pump.
2. Read and follow all warnings regarding USING
HAZARDOUS FLUIDS and Fluid Compati-
bility on page 3.
echnical Assistance:

Advertisement

Table of Contents
loading

This manual is also suitable for:

220-617220-618223-747223-154223-155

Table of Contents