Performance Charts - Graco 241407 Instructions-Parts List Manual

Air-operated diaphragm pumps
Table of Contents

Advertisement

100
(0.7, 7)
80
(0.55, 5.5)
60
(0.41, 4.1)
40
(0.28, 2.8)
20
(0.14, 1.4)
0
0
To find Fluid Outlet Pressure (psi/MPa/bar) at a specific
fluid flow (gpm/lpm) and operating air pressure
(psi/MPa/bar):
1. Locate fluid flow rate along bottom of chart.
2. Follow vertical line up to intersection with selected
fluid outlet pressure curve.
3. Follow left to scale to read fluid outlet pressure.

Performance Charts

Fluid Outlet Pressure
Test Conditions: Pump tested in water with inlet submerged.
A
B
C
2
4
6
(7.6)
(15.2)
(22.7)
FLUID FLOW- -gpm (lpm)
Fluid Pressure Curves
at 100 psi (0.7 MPa, 7 bar) air pressure
A
at 70 psi (0.48 MPa, 4.8 bar) air pressure
B
at 40 psi (0.28 MPa, 2.8 bar) air pressure
C
8
10
12
(45.4)
(30.3)
(37.9)
14
16
(53.0)
(60.6)
308797