Performance Charts - Graco Check-Mate P20LCM Instructions Manual

Hide thumbs Also See for Check-Mate P20LCM:
Table of Contents

Advertisement

Performance Charts

Calculate Fluid Outlet Pressure
To calculate fluid outlet pressure (psi/MPa/bar) at a spe
cific fluid flow (gpm/lpm) and operating air pressure
(psi/MPa/bar), use the following instructions and pump
data charts.
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected
fluid outlet pressure curve. Follow left to scale to
read fluid outlet pressure.
Key: Air Pressure
A
100 psi (0.7 MPa, 7 bar)
B
70 psi (0.5 MPa, 5.0 bar)
C
40 psi (0.3 MPa, 2.8 bar)
D
90 psi (0.63 MPa, 6.3 bar)
05:1 (E) Check-Mate Pumps
cycles/min
0
700
(4.8, 48)
A
500
(34, 3.4)
B
300
(2, 21)
C
100
(0.7, 7)
0
0.2
(0.8)
Fluid Flow in gpm (lpm)
312376N
Note:
Use the following key to determine which fluid is presented in the
corresponding performance charts.
Key:Test Fluid
E
F
G 4,000,000 centipoise silicon test fluid
H
J
60
30
12
(0.3)
8
(0.2)
A
B
5
(0.1)
C
2
(.06)
0.4
0.6
0.8
(1.5)
(2.2)
(2.2)
Calculate Pump Air Flow/Consumption
To calculate pump air flow/consumption (scfm or
3
m
/min) at a specific fluid flow (gpm/lpm) and air pres
sure (psi/MPa/bar), use the following instructions and
pump data charts.
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected
air flow/consumption curve. Follow right to scale to
read air flow/consumption.
No. 10 weight oil
100,000 centipoise sealant test fluid
4,000,000 centipoise weldable rubber base sealer
8,000,000 centipoise pseudoplastic (expandable plastisal
sealer (500,000 centipoise at flow conditions))
11:1 (E) Check-Mate Pumps
0
1400
(9.6, 96)
1000
(6.8, 68)
600
(4.1, 41)
200
(1.4, 14)
0
Performance Charts
cycles/min
30
0.2
0.4
0.6
0.8
(0.8)
(1.5)
(2.2)
(2.2)
Fluid Flow in gpm (lpm)
60
25
(0.7)
17
(0.5)
11
(0.3)
4
(0.1)
33

Advertisement