Overview; Module Features - Pilz PSSu K F EI Operating Manual

Table of Contents

Advertisement

Overview

2
Overview
2.1

Module features

}
Max. 8 modules in one PSSu system
}
Monitoring of 1 axis
}
Configurable within the PAS4000
}
Measured value recorded by proximity switch or encoder
}
Monitoring functions:
– Safe speed monitoring (SSM)
– Safe speed range monitoring (SSR-M)
– Safe operating stop monitoring (SOS-M)
– Safe direction of movement monitoring (SDI-M)
}
Analogue voltage (track S)
}
2 digital FS outputs
– Semiconductor technology
– Single-pole
– Positive-switching
– Current load capacity per output: 0,50 A
– Short circuit-proof
– Overload-proof
– Free from feedback
}
1 digital ST output
– Semiconductor technology
– Single-pole
– Positive-switching
– Short circuit-proof
– Current load capacity per output: 0.5 A
}
1 combined ST input and output "CIO" for networking several devices
}
LEDs for:
– Switch status of each input/output
– Module error
– Module status
}
For failsafe applications in system environment B (automation system PSS 4000)
Accessories:
}
Connector with spring-loaded terminals (necessary for operation)
}
Labelling bracket
}
Labelling strips (sheets)
Operating Manual PSSu K F EI
1003303-EN-03
| 8

Advertisement

Table of Contents
loading

This manual is also suitable for:

312433