Connection Of Proximity Switch And Encoder - Pilz PSSu K F EI Operating Manual

Table of Contents

Advertisement

Wiring
6.6

Connection of proximity switch and encoder

When connecting the encoders and proximity switches, please refer to the chapter entitled
"EMC-compliant wiring".
Sensor types:
}
Configuration: HTL single Z Freq. Ini pnp
– HTL single ended (A,B) + Ini pnp (Z)
– HTL single ended (A,B) + HTL differential (A as Z)
– HTL single ended (A,B) + HTL single ended (A as Z)
}
Configuration: TTL single Z Freq. Ini pnp
– TTL single ended (A,B) + Ini pnp (Z)
– TTL single ended (A,B) + HTL differential (A as Z)
– TTL single ended (A,B) + HTL single ended (A as Z)
Please note:
Tracks /A, /B and /Z must remain free.
Sensor types:
}
Configuration: TTL differential Z Freq. Ini pnp
– TTL differential (A,/A,B,/B) + Ini pnp (Z)
– TTL differential (A,/A,B,/B) + HTL differential (A as Z)
– TTL differential (A,/A,B,/B) + HTL single ended (A as Z)
}
Configuration: HTL differential Z Freq. Ini pnp
– HTL differential (A,/A,B,/B) + Ini pnp (Z)
– HTL differential (A,/A,B,/B) + HTL differential (A as Z)
– HTL differential (A,/A,B,/B) + HTL single ended (A as Z)
}
Configuration: sin/cos 1 Vss Z Freq. Ini pnp
– sin/cos 1 Vss (A,/A,B,/B) + Ini pnp (Z)
– sin/cos 1 Vss (A,/A,B,/B) + HTL differential (A as Z)
– sin/cos 1 Vss (A,/A,B,/B) + HTL single ended (A as Z)
}
Configuration: Hiperface Z Freq. Ini pnp
– Hiperface (A,/A,B,/B) + Ini pnp (Z)
– Hiperface (A,/A,B,/B) + HTL differential (A as Z)
Operating Manual PSSu K F EI
1003303-EN-03
Encoder
Mini-IO
| 50

Advertisement

Table of Contents
loading

This manual is also suitable for:

312433

Table of Contents