Connection of controller and warning lights
6.3

Connection

The connection of warning lights and the most commonly occurring controller (CD (Control Device)) mod-
els is shown below. Possible control device models vary depending on lift model, configuration and the market
concerned.
m
WARNING!
Make sure that the control card is disconnected from the power before connecting. Connecting more
than one controller to each connection is not permitted. Risk of physical damage.
CD19
Black
White
CD3
Brown
Yellow
Blue
Green
Grey
Brown
CD11
Yellow
Blue
Grey
Black (+)
White (-)
CD9
Black
C2+
White
( ), if available)
Brown
Up
Yellow
Down
Blue
Tilt
CD10
Black
C3+
White
( ), if available)
Brown
Up
CD18*
Yellow
Down
* In some cases there may
also be a blue cable on the
CD18. It must NOT be con-
nected in this case.
36
C1+
( ), if available)
Up
Down
Tilt
In
Out
Up
Down
Tilt
Not used
Ctrl 1
Ctrl 2
Ctrl 3
Black
Brown
Yellow
Picture 51. Connection of controller and warning lights
Warning lights
Blue
WL1
WL1 U7 U6 U5 U5 U4 U4 U3 U2 U1 U0
C1+
C1+
Down
Up
2H
Tilt
Out
In
C2+
Down
Up
Tilt
C3+
Down
Up
CD14
C3+
Up
Down
ZT MK2
+
+
U3
U2
U1
+
+
U0
PA-
PA+
CS
WL2
CS+
S5+
S5
S4+
S4
S3+
S3
S2+
S2
S1+
S1
www.zepro.com