Running / connecting cabling

5
Running / connecting cabling
5.1
Maximum power consumption - Minimum recommended conductor
cross-sectional area
Ensure that cable with sufficient wire area is used.
Hydraulic unit 7050
Pump - Motor unit
Minimum recommended conductor cross-sectional area
(copper cables, plus and minus cables)
Control power cable
Main power cable, L < 8m
Main power cable, L = 8 - 15m
Main power cable, L > 15m
Battery
Min. capacity, I
Min. voltage during operation, U
(at lift)
www.zepro.com
(available for lift)
min
min
I
min
-
+
L
I
min
-
+
Picture 42. Maximum power consumption - Minimum rec-
ommended conductor cross-sectional area
12 volt
24 Volt
245 A
145 A
1.5 mm
1.5 mm
2
2
35 mm
35 mm
2
2
50 mm
35 mm
2
2
-
50 mm
2
180 Ah
170 Ah
9 Volt
18 Volt
U
min
L
ZT MK2
NOTE!
Ensure that the lift has
access to the minimum
recommended power
capacity (I
)
Some
min
.
vehicle models have
restrictions regarding
the amount of power
the lift can access from
the existing battery.
U
min
31