FIREBOX
Installation Instructions
®
INSTALLATION OF
HOT-AIR CIRCULATION KITS
There are three kits for ducting hot air that in-
clude everything necessary for the following
three cases:
Kit one (Figs. D - E)
only the fireplace room
- remove the two pre-cut plugs from the Fire-
box
cover by pressing inwards;
®
- fasten the two connectors on the holes in
the hood;
- insert the two pipes and fi x them with the
clamps provided;
- attach the two outlet "B2" frames with con-
nection pipe to the top of the mantel;
- attach the two slots "G1" to the bottom of
the mantel;
- connect the two aluminium connection
pipes and fasten with clamps; fi t the two front
grilles and click them into place.
Kit two (Fig. F)
fireplace room, plus one adjacent room
Fig. D
Fig. G
Proceed as for kit one, fi tting one complete
outlet "B1" to the top of the mantel instead of
two "B2", and an outlet "B3" to the wall of the
room to be heated.
At the base of the mantel, only one slot "G1"
is required.
Kit three (Fig. G)
fireplace room, plus two adjacent rooms
Proceed as for kit one, fi tting the two "B3" out-
lets to the walls of the rooms to heat instead
of the two "B2" outlets.
This kit entails the use of a slot (G1) in the
top of the mantel to allow ventilation inside
the mantel itself.
NATURAL CONVECTION
This occurs when the air circulates naturally in
the cavity and ducting by exploiting convec-
tion (the physical principle that causes hot air
to rise).
FORCED VENTILATION (Fig. H)
This is achieved with the use of two fans (17)
Fig. E
Fig. H
inserted in the lower part of Firebox
, a tem-
®
perature thermostat housed next to one of the
two fans and a two-speed switch (18) to be
placed near the fi replace.
Connecting the forced-ventilation equip-
ment:
- connect the switch to the fans by inserting
connector (M) into connector (F).
- connect the switch to the 230 VAC mains
using the plug (S).
Operation of the two-speed switch:
- to start the fans, set the switch to "manual"
(fi rst or second speed as desired).
- to stop the fans set the switch to "auto-
matic"
N.B.: in the "automatic" position, the fans op-
erate automatically when the air temperature
is above 50°C, to prevent damage from ex-
cessive heat, and then
they remain off at lower temperatures.
Fig. F
-
26 -