USER CONTROLS (REMOTE CONTROL)
- ON/OFF
- Switch-on/switch-off
- Manual mode setting
Power setting
Fan setting
- Automatic mode setting
Temperature setpoint setting
Fan setting
- RELAX function
- From the Menu page:
Load Pellets (SCREW LOAD)
Stand By
Crono-Program
Night
Date / time
Display
Language
Beep (BUZZER)
Info (technician only)
Technical menu (technician only)
We describe the procedures below.
ON/OFF
hold the ON/OFF button down to turn the product ON.
When ON, the product has a flame (ignition phase,
etc.) when there is a heating demand.
34
Switch-on/Switch-off
The ON/OFF button switches the product on (starts
the ignition phase) or off (starts the switch off phase)
manually in Manual mode only.
In Automatic mode, the product responds to the
heating demand.
Setting Manual/Automatic
Press the OK button for 2 seconds to switch from
manual to automatic or vice versa.
In Manual mode, the display reads "Man"
In Automatic mode, the temperature displays.
In automatic- Room Temperature Setting
Set Room Temperature (read by the remote control,
this should be be positioned in the room the product
is installed in)
Set the temperature setpoint (Set) with the "+" and "-"
buttons.
In manual- Power setting
Set the power level (displayed by the flame symbol)
with the "+" and "-" buttons.
The power level displays next to the flame symbol.
USER INSTRUCTIONS
MODELS WITH DUCTED VENTILATION
The Pellkamin is equipped with two fans, defined in the
control logic as fan 2 and 3, and displayed as positions
2 and 3 (see below).
The two fans can be adjusted separately. First adjust
fan 2 and then fan 3, as described below.
Ventilation setting
Press "OK" once
The fan setting displays, next to the blade symbol
representing the fan.
Set the fan level with the "+" and "-" buttons.
The blades fill in to indicate the current setting.
Confirm by pressing the OK button for 2 seconds
The fan settings can also follow the power demand
(decrease when the power is decreased or increase
vice versa).
To activate this mode, press the + button to above the
maximum setting. The letter "A" will appear next to the
blade symbol.
To ensure that the speed of the fans varies according
to room temperature demand, contact CAT, who will be
able to fit dedicated sensors.
In the event of the installation of the optional front fan,
fans 2 and 3 will not be present and the Edilkamin
technician will explain the new operating mode during
installation.
MODELS WITH FRONTAL VENTILATION
Follow the instructions below to manually regulate the
power levels of the fan.
Press "OK" once
The fan setting displays, next to the blade symbol
representing the fan.
Set the fan level with the "+" and "-" buttons.
The blades fill in to indicate the current setting.
Confirm by pressing the OK button for 2 seconds
The fan setting can also follow the room temperature
demand (reduce when the temperature is close to the
desired temperature or increase vice versa).
To activate this mode, press the + button to above the
maximum fan setting. The letter "A" will appear next to
the blade symbol.
THE NUMBER NEXT TO THE FAN BLADE OR FLAME
ONLY DISPLAYS WHILE THE SETTING IS BEING
MADE.