INSTALLATION VENTILATION KIT
1. position the fan kit (A) after rotating it by 180° if
it is to be positioned to the left of the product, if
necessary;
2. Position the vent/s (B) (not provided with the
product) or provide other outlets for the warm air
pipe;
3. connect the Ø 100 mm pipe * (C) from the product
to the fan kit
4. connect the Ø 60 pipe (D) from the fan kit to the
vent, .
5. make the electrical connections.
Please see the picture of an exemple with pellet loa-
ding hatch (E) and vent Label (F)
* Please INSULATE the Ø 100 mm
PIPE FROM the PRODUCT to the FAN
KIT
A
VERSIONS WITH DUCTED VENTILATION (1/4)
DUCTED VENTILATION
F
B
D
C
*
F
NOTES
the Ø 100 mm connection section between the
product and the fan is a maximum 1.5 m. in length.
Position the fan low down, preferably close to the
base of the appliance, This prevents the heat from
ruining the fan. It can also be placed above the
appliance, so long as there is no danger of over-
heating.
The maximum recommended ducting length (Ø
60 mm pipe) is 8 m.
The instructions for installing the vents are
included with the vents themselves
E
*
*
A
19