12. The harness (714) has an M8 connector and an
M12 connector. Connect the M12 connector that
was originally connected to port 3 on the Electric
Driver (AB) to the M12 connector on the harness
(714). Connect the M8 4 pin connector to the
solenoid on the platen valve (701).
714
M8
Connector
M12
Connector
715
714
F
. 74
IG
13. Remove the 1/4 NPT plug from the Integrated Air
Controls (AG). See Integrated Air Controls (AG)
on page 15.
14. Insert the elbow fitting (716) into the Integrated Air
Controls (AG).
333586E
15. Connect the nylon tube (715) to the elbow fitting
(716) and the platen valve (701).
F
. 75
IG
Kits and Accessories
715
716
91