Graco E-Flo Installation Manual page 49

Iq dispense system
Table of Contents

Advertisement

20, 30, and 60 Liter Platen
1. Follow the Pressure Relief Procedure on page 39.
2. Turn off power to the ram:
a. If using an ambient Single Ram Supply System,
turn the red Disconnect Switch (AZ) OFF.
b. If using a heated Single Ram Supply System, turn
the red Disconnect Switch (AZ) OFF.
c. If using an ambient Tandem Ram Supply System,
turn the red Disconnect Switch (AZ) OFF on the
Ram Supply Unit that requires repair only.
d. If using a heated Tandem Ram Supply System,
turn the red Disconnect Switch (AZ) OFF on the
Ram Supply Unit that requires repair only.
3. Loosen two 5/16 in. screws (462) from Platen (AD).
4. Carefully pull Pump away to prevent damage to Pump
inlet. If using a Pump with an intake adapter, remove
screws (472), adapter (471), and o-rings (463) from
Pump inlet.
333586E
462
Ambient Platen
462
Heated Platen
F
. 44: 20 liter mounting kit
IG
Repair
463
463
49