Graco E-Flo Installation Manual page 51

Iq dispense system
Table of Contents

Advertisement

5. Raise the Driver (AB):
a. Loosen nut (105a) under Ram bar and thread it
down the threaded rod (106) to the lift ring
adapter (107) holding the Driver (AB). Use
wrench on nut (105) on top of Ram bar to raise
Driver (AB).
105
105a
F
. 45
IG
b. For Driver (AB) with smaller Platens (AD) and
all ram supply units: See procedure for D60 3
in. Dual Post Ram Supply Units on page 51.
6. See Disconnect Pump from Platen on page 48 to
disconnect the Platen (AD) from the Displacement
Pump (AC).
333586E
7. Use two people to lift out the Displacement Pump
106
107
F
IG
D60 3 in. Dual Post Ram Supply Units
1. Follow the Pressure Relief Procedure on page 39.
2. Turn off power to the ram:
3. See Disconnect Displacement Pump in your
(AC).
. 46
a. If using an ambient Single Ram Supply System,
turn the red Disconnect Switch (AZ) OFF.
b. If using a heated Single Ram Supply System,
turn the red Disconnect Switch (AZ) OFF.
c. If using an ambient Tandem Ram Supply
System, turn the red Disconnect Switch (AZ)
OFF on the Ram Supply Unit that requires
repair only.
d. If using a heated Tandem Ram Supply System,
turn the red Disconnect Switch (AZ) OFF on the
Ram Supply Unit that requires repair only.
Pump packages manual.
Repair
51

Advertisement

Table of Contents
loading

This manual is also suitable for:

333586e

Table of Contents