Option 215 Limitations

Frequency Bands

The PSA Series spectrum analyzers have up to six frequency bands
depending on the maximum frequency capability of the model. These
frequency bands are shown in the table below.
Option 215 cannot sweep across PSA frequency band boundaries. Any
frequency sweep required for a measurement must be kept entirely
within one of these bands. One way to work around this limitation is to
write an external control program to break the measurement down into
two or more sweeps, each of which is confined to the bands listed below.
Table 1-2
Frequency Bands in the PSA Series analyzers
(Microwave Preselector On)
Band
Number
0
1
2
3
4
5
6
Table 1-3
Frequency Bands in the PSA Series analyzers
(Microwave Preselector Off)
Band
Number
1
2
3
4
5
6
7
Chapter 1
Frequency Range
3.0 Hz - 3.05 GHz
2.85 GHz - 6.6 GHz
6.2 GHz - 13.2 GHz
12.8 GHz - 19.2 GHz
18.7 GHz - 26.8 GHz
26.4 GHz - 31.15 GHz
31.0 GHz - 50.0 GHz
Frequency Range
3.0 GHz - 6.6 GHz
6.2 GHz - 13.2 GHz
12.8 GHz - 19.2 GHz
18.7 GHz - 26.5 GHz
26.4 GHz - 31.15 GHz
31.0 GHz - 41.0 GHz
40.5 GHz - 50 GHz
Getting Started
Option 215 Limitations
Overlap
with Next
Band
200 MHz
400 MHz
400 MHz
500 MHz
400 MHz
150 MHz
N/A
Overlap
with Next
Band
400 MHz
400 MHz
500 MHz
100 MHz
150 MHz
500 MHz
N/A