Table 8: Electrical Specification Of The Light Module; Figure 32: Calculation The Torque Load Of The Light Module; Figure 33: Electrical Polarity Of Fill Light Cable - Omron TM Series Hardware Installation Manual

Medium & heavy payload
Hide thumbs Also See for TM Series:
Table of Contents

Advertisement

2.
The maximum allowed payload of the robot: the weight of the light module must match the relative
relationship between the maximum allowed payload and the center of gravity offset distance. If the
tool end flange goes with additional applications, it is required to generate the equivalent center of
gravity for its position and total load from the combination of the light module and the application
tool as well as follow 4.2.1.5 Payload and Torque of this manual.
3.
Refer to 4.4 for Working distance and field of view of TM Robot's EIH camera.
4.
Electrical Specification of the Light Module
Voltage:
The total current of the tool end and the light module has to be lower than 1.5A.
Fill light cable:
Medium & Heavy Payload Series-Hardware Installation Manual TM12/14 Series Hardware Version: 3.2

Figure 32: Calculation the Torque Load of the Light Module

24V

Table 8: Electrical Specification of the Light Module

Figure 33: Electrical Polarity of Fill Light Cable

Light Module
Current:
< 900mA
(+)
(-)