2
CC-Link IE Field Network Basic
2.1

Functions and configuration

This manual describes communication with the MR-JET-_G servo amplifiers using CC-Link IE Field Network Basic
communication protocol. Refer to the following manual when using CC-Link IE Field Network Basic.
MR-J5-G/MR-J5W-G User's Manual (Object Dictionary)

Outline

CC-Link IE Field Network Basic is a protocol that utilizes 100 Mbps for general-purpose Ethernet communications. By taking
advantage of using general-purpose Ethernet, TCP/IP communications (HTTP, FTP, and the like) can also be used together,
allowing for a high flexibility system configuration.
The servo amplifier can be connected to a programmable controller CPU or IPC that supports the CC-Link IE Field Network
Basic master station. Positioning operation is possible in profile position mode and point table mode, in which position data
(target position) is given via the controller to perform positioning operation.

System configuration

A configuration example is as follows.
A controller can control up to 16 axes per group, for a total of 64 axes of servo amplifiers.
Controller, IPC
Controller, IPC
2 CC-Link IE Field Network Basic
54
2.1 Functions and configuration
HUB
MR-J5
MR-J5
Personal
MR Configurator2
computer
MR-J5