3
CC-LINK IE FIELD NETWORK MODULE FB
3.1
M+FX5CCLIEF_DeviceRead
Name
M+FX5CCLIEF_DeviceRead
Overview
Item
Overview
Symbol
Labels
■Input label
No.
Variable name
(1)
i_bEN
(2)
i_stModule
(3)
i_u2TargetAddress
(4)
i_uDataLength
3 CC-LINK IE FIELD NETWORK MODULE FB
24
3.1 M+FX5CCLIEF_DeviceRead
Description
Reads data from a specified device in the programmable controller of another station.
M+FX5CCLIEF_DeviceRead
(1)
B
:
i_bEN
(2)
DUT
:
i_stModule
(3)
UW
:
i_u2TargetAddress
:
(4)
UW i_uDataLength
:
(5)
S
i_s32TargetDevice
(6)
UW i_uChannel
:
(12) pbi_uCPU_Type
(13) pbi_uResendCountMax
(14) pbi_uTimeUnit
(15) pbi_uMonitorTime
(16) pbi_bStationSpecific
(17) pbo_uResendCount
(18) pbo_u4ErrTime
(19) pbo_uErrNetworkNo
(20) pbo_uErrStationNo
Name
Data type
Execution command
Bit
Module label
Structure
Target station address
Word [unsigned]
(0..1)
Read data length
Word [unsigned]
o_bENO
:
B
(7)
o_bOK
:
B
(8)
o_bErr
:
B
(9)
o_uErrId
:
UW
(10)
o_uReadData
:
UW
(11)
Range
Description
ON, OFF
ON: The FB is activated.
OFF: The FB is not activated.
The setting range
Specify the module label of the FX5-CCLIEF.
differs depending on
the module label.
Specify the network number and station number for the
target station. To specify with a label, use an array for
the data type.
1st word
2nd word
Station number of Ethernet or CC-Link IE Controller
Network
• 1 to 120
Station number of CC-Link IE Field Network
• 125: Master station
• 126: Master operating station
• 1 to 120: Local station, remote device station,
intelligent device station, submaster station
1 to 960
Specify the number of words to be read.
• When reading data from RCPU, QCPU, LCPU, or
FX5CPU: 1 to 960
• When reading data from QnACPU: 1 to 480
b15
Network number: 1 to 239
Station number
b0