Installation; Mounting Location - Endress+Hauser Proline Promass I 100 Technical Information

Coriolis
Hide thumbs Also See for Proline Promass I 100:
Table of Contents

Advertisement

Mounting location

38
Calculation of the maximum measured error as a function of the flow rate
Flow rate
ZeroPoint
100
³
BaseAccu
ZeroPoint
<
100
BaseAccu
Calculation of the maximum repeatability as a function of the flow rate
Flow rate
½
ZeroPoint
100
³
BaseRepeat
½
ZeroPoint
<
100
BaseRepeat
Example for max. measured error
E [%]
2.5
2.0
1.5
1.0
0.5
0
0
5
10
15
20
E
Error: Maximum measured error as % o.r. (example)
Q
Flow rate as %
Design fundamentals (→  37)

Installation

No special measures such as supports are necessary. External forces are absorbed by the construction
of the device.
To prevent measuring errors arising from accumulation of gas bubbles in the measuring tube, avoid
the following mounting locations in the pipe:
• Highest point of a pipeline.
• Directly upstream of a free pipe outlet in a down pipe.
Maximum measured error in % o.r.
± BaseAccu
A0021332
ZeroPoint
±
100
MeasValue
A0021333
Maximum repeatability in % o.r.
A0021335
ZeroPoint
±
½
MeasValue
A0021336
25
30
35
40
45
50
55
Proline Promass I 100
100
60
65
70
75
80
85
90
Endress+Hauser
A0021339
A0021334
A0021340
A0021337
95
100
Q [%]
A0016709

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Proline Promass I 100 and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents