Power Specifications; Shipping Carton Space Requirements - Oracle Exadata Storage Server X6-2 High Capacity Installation Manual

Table of Contents

Advertisement

Set conditions to the optimal temperature and humidity ranges to minimize the chance of
downtime due to component failure. Operating the storage server for extended periods at or
near the operating range limits, or installing it in an environment where it remains at or near
nonoperating range limits, could significantly increase hardware component failure.

Power Specifications

The storage server uses AC power. The values in the following table are the power supply
specifications.
Note -
power numbers for the power supply used in the system. The numbers are not a rating of the
actual power consumption of the system.
TABLE 4
Parameter
Voltage (nominal)
Input current (maximum)
Frequency

Shipping Carton Space Requirements

The following table lists the dimensions and weights for the shipping cartons that contain the
Oracle Exadata Storage Server X6-2 High Capacity.
TABLE 5
Requirement
Shipping carton height
Shipping carton width
Shipping carton length
Shipping carton weight
When the Oracle Exadata Storage Server X6-2 High Capacity is unloaded at your site, leave
the storage server in its shipping carton until it arrives in its installation location. Use a separate
The power dissipation numbers listed in the following table are the maximum rated
Power Supply Specifications
Shipping Carton Specifications
Specification
30.5 cm (12 inches)
59.9 cm (23.6 inches)
98.4 cm (38.7 inches)
5.8 kg (12.8 lbs)
AC Requirement
100 to 127/200 to 240 VAC
12 A–8.5 A @ 100–127 VAC
5.7 A @ 200–240 VAC
50/60 Hz (47 to 63 Hz range)