Rc: Time-Controlled Events With The Internal Real Time Clock - WEIGL ProCommander LX Instruction Manual

Hide thumbs Also See for ProCommander LX:
Table of Contents

Advertisement

& means „modulo" which means, that any time the value is
reached the command is executed.
&05:00 means, that all 5 minutes the downstream command
will be executed.
c is the signal for external clock. So if an external clock is
connected, the specified value is compared to this clock.
Example:
!tm01:20# → if the time reached 1 minute 20 seconds after
the start-up or plug in of the card, then the following command
will be executed.
!t&05:00# → all 5 minutes the following command will be
executed.
!tc08:00# → at 8 o'clock (time from the external clock) the
following command will be executed.
!rc: Time-controlled events with the internal real time
clock
That you can use this function you have to insert a battery
first, for further information go to 5.2.4 RealTimeClk – LEVEL 2.
Based on the date and time values of the real time clock
commands can be executed.
Control.ini
73