16.4 Assignment Remote 1-16, Open-Collector 1-16

Remote 1-8/ Relay 1-8
Connector
Upper row
1
Input 1
2
Input 2
3
Input 3
4
Input 4
5
Input 5
6
Input 6
7
Input 7
8
Input 8
9
Power-
Supply +
10
GND
1
Common Cathode of Open-Collector 1-8 incl. power supply+, if jumper 1 is closed.
2
Common Cathode of Open-Collector 9-16 incl. power-supply+, if jumper 2 is closed.
Remote 9-16/ PWM 1-8
Lower row
Upper row
Digital
Input 9
Output 1
Digital
Input 10
Output 2
Digital
Input 11
Output 3
Digital
Input 12
Output 4
Digital
Input 13
Output 5
Digital
Input 14
Output 6
Digital
Input 14
Output 7
Digital
Input 16
Output 8
Common
Power-
1
Cathode
Supply +
GND
GND
Appendix
Lower row
Digital Output 9/
PWM 1
Digital Output
10/ PWM 2
Digital Output
11/ PWM 3
Digital Output
12/ PWM 4
Digital Output
13/ PWM 5
Digital Output
14/ PWM 6
Digital Output
15/ PWM 7
Digital Output
16/ PWM 8
Common
2
Cahtode
GND