List Of Components - Nibe EMINENT-35 E Installation And Maintenance Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

EMINENT-E/CU/R 35, 55, 100, 120
Dimensions and location of components
41
45
42
25
1
General
* Requisite space (EMINENT-E) for replacement/inspec-
tion of the sacrificial anode.
35 litres:
180 mm
55 litres:
250 mm
100 litres:
390 mm
With vertical suspended assembly a chain anode can be
used, this only requires 180 mm above the water heater.
The serial number (95),should always be stated
with all correspondence with NIBE.
072 _ _ _ _ _ _ _ _ _ _ _
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Rights to make any design or technical modifications are reserved.
©NIBE 2012.
INSTALLATION AND MAINTENANCE INSTRUCTIONS
5
2
22
43
23
95
184
54 40
467
EMINENT-E/CU/R 35, 55, 100, 120
3
40
min 145
12
*

List of components

1
Power cord with earthed plug, length 850 mm
2
Plastic cover, electrical connection box
3
Plastic cover, anode (EMINENT-E)
5
Thermostat/temperature limiter
6
Immersion heater, RAR 14-112
12 Hanging bracket
13 Securing bracket
22 Shutoff/non-return valve
23 Safety/drainage valve
25 Mixing valve
40 Sacrificial anode (EMINENT-E)
41 Cold water connection, compression fitting
Ø 15 mm
42 Mixed water connection, compression fitting
Ø 15 mm
43 Connection safety/drainage valve, compression ring
coupling Ø 15 mm
45 Venting screw (for air supply when draining)
95 Serial number sticker
6
EMINENT 35 = 565
EMINENT 55 = 750
EMINENT 100 = 1120
EMINENT 120 = 1304
min 200