GB Technical specifi cations

Components and dimensions

5
6
7
11
2
95
200
Ø670
Ø750
6
10
4
3
1

List of components

1
Cold water connection, G50, internal thread
2
Hot water connection, G50, internal thread
3
HWC connection, G20, internal thread
4
HWX connection, G32, internal thread
5
Connection for thermometer, pressure gauge, ther-
mostat, G15 internal thread
6
Connection for immersion heaters, G50, internal
thread.
7
Draining valve
10 Lifting eye
11 Adjustable feet
95 Serial number sign
Technical specifi cations
Max. operating pressure in hot water heater
Max. operating temperature in hot water heater
Volume
Diameter
Height
Net weight
Max. output
Heat content at 80°C
Equivalent amount of hot water (40°C)*
Heating-up time 10-60°C, 2 x 9 kW
Corrosion protection
Item number
*
With an incoming temperature of 10 °C and hot water usage of
48 l/min.
Accessories
K11 Junction box

Enclosed kit

Cover discs
Installation and Maintenance Instruction
Insulation plug
EKS 500
approx. 160 kg
1 050 litres
Immersion heater IU 31 - IU 311
10 bar
95 °C
500 litres
750 mm
1780 mm
2 x 9 kW
46.5 kWh
100 min
Copper
075 430