Table of Contents

Advertisement

8
Radiometric measurement
Name
Jitter
Fixed delay
Manual delay
Integration Time
8.7.1.4 LED description
LED status
Off
Green
Orange
Blinking green
Blinking orange

8.7.2 Sync Out

8.7.2.1 General
The Sync Out signal is synchronous with the Sync In or the frame rate (if Sync In is not
selected). It can be used to synchronize other events with the camera. It is a TTL signal.
The Sync Out setup is described in section 6.4.7 Synchronizing the camera to an exter-
nal signal, page 24.
8.7.2.2 Characteristics
Name
Amplitude
Max frequency
Impedance
Minimum pulse width
Protection
Connector
1. Example: If the detector is working at 100 in full frame, then the maximum frequency will be 100.
#T810207; r. AA/43061/43086; en-US
Value
20 ns
690 ns
Description
No signal detected. Check the connection and
signal levels.
Signal detected and the signal voltage is correct
but the signal is continuous.
Signal detected but the signal voltage is
incorrect.
Signal detected.
LED is blinking at the signal frequency.
Signal voltage is correct.
Signal detected.
LED is blinking at the signal frequency.
Signal voltage is incorrect.
Value
TTL signal 0/+5 V
Maximum frame rate of the camera for a given de-
tector configuration
High impedance
300 ns
Voltage peaks (500 V/<1 ns)
Overvoltage (15 V)
Reversed polarity
Coaxial BNC jack
Notes
1 pixel clock (50 M)
Propagation through the back
panel card + propagation from
the FPGA to the detector
Set by the user
Set by the user
1
42

Advertisement

Table of Contents
loading

Table of Contents