Mounting Procedures - ClipperCreek LCS Series User Manual

Hide thumbs Also See for LCS Series:
Table of Contents

Advertisement

CAUTION: A 3-phase delta-connected transformer secondary without
a center-tap on one leg cannot be used with the LCS. No "Neutral"
point is available to be connected to ground for ground-fault protection.
The LCS will not allow the contactor to close if it does not sense the
presence of a Ground wire connected to a "Neutral" point on the
transformer secondary.
ATTENTION: Un triphasé triangle-connecté transformateur
secondaire sans centre-tap sur le terminal ne peut pas être utilisé avec la
LCS. Aucun point "Neutre" est disponible pour être connecté à Mise à
la Terre pour protection de défaut à la terre. Le LCS ne permettra pas le
contacteur de fermer si elle ne détecte pas la présence d'un fil de Masse
connecté à un point "Neutre" sur le secondaire du transformateur.

MOUNTING PROCEDURES

Locate the wall mounting position of the EVSE:
On the hardwired LCS, the three service conductors are shielded by three
feet of flexible conduit. The LCS must be positioned such that this conduit
can reach a nearby service panel or junction box.
On the plug-in LCS-P, the NEMA plug head is connected by nearly one foot
of cable to the top side of the LCS-P. The LCS-P must be positioned such
that this plug can safely be inserted into a wall-mounted NEMA socket.
Position the bottom of the charge station at a comfortable height and at least
18 inches above the ground. Ensure that the LEDs on the front panel of the
EVSE can clearly be seen by anyone who will be operating the device.
The LCS has four mounting holes spaced in a 2" wide by 10" tall
rectangular pattern. Use a template to mark hole locations on the wall.
WARNING: For safety, always turn off input power to the charge
station at the circuit breaker panel prior to plugging it in or wiring
it to the service lines. Likewise, turn off the circuit breaker prior to
unplugging it or disconnecting the unit from the service lines.
AVERTISSEMENT: Pour sécurité, toujours désactiver le courant
d'entrée de la station de recharge au niveau du disjoncteur du panneau
avant de le brancher ou de câblage à les lignes de service. De même,
coupez le disjoncteur avant de le débrancher ou déconnecter l'unité à
partir des lignes de services.