5 Installation

5.4 Mounting

5.4
46
Mounting
CAUTION
Operational malfunctions
Use of unsuitable or improperly prepared cables, as well as incorrect wiring will
mean that neither the values stated in the technical data nor the electromagnetic
compatibility (EMC) can be ensured.
Only use cables prepared by specialists.
The cables used must be prepared according to the interface description in this
document.
The wiring instructions for the relevant interface must be observed when wiring
the device.
Any generally applicable regulations and standards must be fulfilled.
CAUTION
Device condensation
If the device is or was exposed to climatic changes (temperature fluctuation, air hu-
midity) moisture can form on or in the device (device condensation). In this case,
there is a risk of short-circuit.
The device must not be switched on when device condensation is present.
If condensation is present on the device, or if it was exposed to temperature fluc-
tuations, it must be allowed to adjust to room temperature (do not expose the de-
vice to the direct heat of heating devices) prior to commissioning.
1
Check the device for damage in transit.
The device must only be installed and commissioned in perfect technical condition and
in compliance with this document.
2
Mount the device in the control cabinet, control panel or the control desk. See Chapter 5.4.1
Mounting the device,
47.
3
Connect the device as required.
Follow the instructions on wiring the relevant interface. See Chapter 5.3 Interfaces,
The device is not provided with an On/Off switch. If the power supply is not provided
with a switch, the device will start up (boot) as soon as it is connected to the power sup-
ply.
XV-102 Micro Panel MN04802004Z-EN—February 2013 www.eaton.com
www.comoso.com
23.