^AB ^D
COMMAND
28
Software Bank Switch #8: A non-volatile command used to set the various
functions identified below.
^AB12345678
Position:
1
2
3
4, 5
6
7
8
^A
^D
COMMAND
X
29
Printer Statistics:
0
Print Statistics to the serial port.
1
Print Statistics on a label.
2
Clear the Printed Labels variable in the statistics.
3
Clear the Printed Inches variable in the statistics.
32
Restart Printer: Restores the printer to power-up settings. Also used to set
the non-volatile fields in memory.
33
Display Model and Revision Number
XX
36
Adjust Contrast Base: This is a non-volatile command that adjusts the
contrast base value. The ^Axx specifies a value from 10% to 200%.
X
39
Auto-Size Label:
0
Clears the auto-size values determined by the ^A1^D39 command.
1
Uses values obtained for the variables instead of what the user supplies in the
header of the format file.
2
Automatically sizes the label and displays on the screen the values for the
header variables.
3
Same as ^A2^D39, but prints the values on a label, instead of on the screen.
5
Diagnostic Mode (Tick-Tick)
6
Diagnostic Silent Mode (Tick-Tick)
40
Clears Commands 41 through 51
XX
41
Load Number of Fields in Layout (HFM): The ^Axx specifies the value.
XX
42
Load Label Width in dots (LSX): The ^Axx specifies the value.
XX
43
Load Label Height in dots (LSY): The ^Axx specifies the value.
XX
44
Load the Web Size in dots (WEB): The ^Axx specifies the value.
XX
45
Load the Gap Size in dots (GAP): The ^Axx specifies the value.
334M Operator's Manual - 880060-0110
Reserved
Reserved
1 = Disable Line Feeds; 0 = Enable
Reserved
1 = Enable Presenter Option; 0 = Disable
1 = Enable Reflective Stock Out Detection; 0 = Disable
1 = Enable LTS Jam Detection; 0 = Disable
13-9