^AB ^D
COMMAND
25
Software Bank Switch #5: A non-volatile command used to set the various
functions identified below.
^AB12345678
Position:
1
2
3
4
5
6
7
8
26
Software Bank Switch #6: A non-volatile command used to set the various
functions identified below.
^AB12345678
Position:
1
2
3
4
5
6
7
8
27
Software Bank Switch #7: A non-volatile command used to set the various
functions identified below.
^AB12345678
Position:
123
456
7
8
13-8
1111 = US English (7 bit)
1 = Enable Single Button Error Clear; 0 = Disable
1 = Display >BUTTON PRESSED<; 0 = Disable
1 = TOF sensor is transmissive; 0 = TOF is reflective
1 = Enable TOF on Power-up; 0 = Disable
1 = Button is TOF; 0 = Button is Defined by SW#2 bit4
1 = Enable AutoLoad; 0 = Disable
1 = AutoLoad+TOF; 0 = Autoload+FF
1 = Enable Status Byte Mode; 0 = Disable
1 = Enable >TRAY FULL< response; 0 = Enable Test Pattern
Reserved
1 = Enable Pre-Stock Out Feature; 0 = Disable
1 = Enable >STOCK NOT LOADED< response; 0 = Disable
Reserved
1 = General Purpose I/O Enable; 0 = Custom I/O Enable
1 = Enable Takeup Control; 0 = Enable Cutter Control
Reserved
Reserved
Reserved
1 = Disable System Parameter Saving; 0 = Enable
1 = Enable Finish Mode; 0 = Disable
334M Operator's Manual - 880060-0110
Need help?
Do you have a question about the 334M and is the answer not in the manual?