Techical Specfications - ACME Building wash User Manual

Hide thumbs Also See for Building wash:
Table of Contents

Advertisement

2.Techical Specfications

- New member of Visio architectural lightings, specially designed to replacing the traditional
outdoor 400W discharge fixtures.
- Great heat ventilation and heavy duty design to ensure reliable performance under harsh
environment
- It features 90pcs×3W CREE LEDs provides powerful output
- Various beam angles, ideal for different applications – for the illumination of buildings, bridges,
stadium, landscapes, theme parks and more.
Key Facts:
◇ Die-cast housing and thermal control for the reliable performance
◇ 17000 Lumen Output
◇ 1 KHz refreshing frequency, flicker-free under HD camera
◇ Barn door is available upon request (sold separately)
BW-903 CW AR:
 Input Voltage:
 Power Consumption:267W
 Light Source:
 Beam Angle:
 Lumen Output:
 Color Temperature:
 IP Rating:
 Weight:
 Dimension:
AC 100-240V 50/60Hz
90×3W CREE Cold White LEDs
6°, 15°, 25°, 40°, 60°, 80°
>17000lm
5300~5900K
IP66
15.6Kgs
385×400×195mm