  • Page 2: Table Of Contents

    CONTENTS 1. Safety Instructions ..................2 2. Technical Specifications ................. 3 3. Control Panel ....................5 4. Installation ..................... 6 5. How To Set The Unit ..................7 5.1 Main Function ..................7 5.2 Home Position Adjustment ..............13 6. Control By Universal DMX Controller ............15 6.1 DMX512 Connection ................
  • Page 3: Safety Instructions

    1. Safety Instructions Please read the instruction carefully which includes important information about the installation, usage and maintenance. WARNING Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction manual. Important: Damages caused by the disregard of this user manual are not subject to warranty.
  • Page 4: Technical Specifications

    DO NOT operate in a dirty or dusty environment. DO clean the fixture regularly.  DO NOT touch any wire during operation as there might be a hazard of electric shock.  Avoid entanglement of the power cord with other wires. ...
  • Page 5 Construction: Display: OLED display Data In/Out: 3-pin XLR (5-pin XLR is optional) Power In/Out: Power Connector in/out Protection Rating: IP20 Features: Compact design, light in weight Multiple units can be split-jointed horizontally with connecting board LED can be controlled pixel by pixel, delivering versatile effects Dimensions/ Weight: 500x152x500mm, 12.6kgs 19.7”x6”x19.7”in, 27.8lbs...
  • Page 6: Control Panel

    3. Control Panel 1. Display: To show the various menus and the selected function 2. Button: MENU To enter into move backward or leave the menu To go backward to move up in the menu DOWN To go forward to move down in the menu ENTER To perform the desired functions 3.
  • Page 7: Installation

    4. Installation The fixture should be fixed on the clamp. Always ensure that the unit is firmly fixed to avoid vibration and slipping off during operation. Ensure that the trussing or area of installation must be able to hold 10 times the weight without any deformation. Always install a safety cable that can hold at least 12 times the weight of the fixture when installing.
  • Page 8: How To Set The Unit

    3. Multi-machine assembly As shown in the figure, loosen the screws (A) of the splicing plate of the fixture. Then join the fixtures together in pairs and move the splicing plate, tighten the screws and fix them on the two fixtures;...
  • Page 10 DMX Settings To select DMX Settings, press the ENTER button to confirm, use the UP/DOWN button to select DMX Address, Channel Mode, No DMX State or View DMX Value. DMX Address To select DMX Address, press the ENTER button to confirm. Use the UP/DOWN button to adjust the address from 001 to 366/496/502/509/469/369, press the ENTER button to store.
  • Page 11 Optically Linear: The increase in light intensity appears to be linear as DMX value is increased. Square Law: Light intensity control is finer at low levels and coarser at high levels. Inverse Square Law: Light intensity control is coarser at low levels and finger at high levels. S-Curve: Light intensity control is finger at low levels and high levels and coarser at medium levels.
  • Page 12 Language Select Language, press the ENTER button to confirm, present mode will blink on the display, use the UP/DOWN button to select English or Chinese. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode. Fixture Test To select Fixture Test, press the ENTER button to confirm, use the UP/DOWN button to select Auto Test or Manual Test...
  • Page 13 LED Use Hour To select LED Use Hour, press the ENTER button to confirm, use the UP/DOWN button to select Total LED Hour, LED On Hour or LED Hours Reset, press the ENTER button to store. Select LED Hours Reset, press the ENTER button to confirm, use the UP/DOWN button to select No or Yes, press the ENTER button to store.
  • Page 14: Home Position Adjustment

    RDM FUNCTIONS Select the MANUFACTURER menu to display the manufacturer of the fixture. Select the SOFTWARE VERSION menu and the program version number of the fixture will be displayed. Select the DMX START ADDRESS menu to change the DMX512 address (001-512). Select the DEVICE MODEL DESCRIPTION menu to display the model of the fixture.
  • Page 15 Enter offset mode, select Red, press the ENTER button to confirm, the present position will blink on the display, use the UP/DOWN button to offset the value from 0 to 255, press the ENTER button to store. Press the MENU button to exit. Green Enter offset mode, select Green, press the ENTER button to confirm, the present position will blink on the display, use the UP/DOWN button to offset the value from 0 to 255, press the ENTER button...
  • Page 16: Control By Universal Dmx Controller

    6. Control By Universal DMX Controller 6.1 DMX512 Connection 1. At last unit, the DMX cable has to be terminated with a terminator. Solder a 120-ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the DMX-output of the last unit.
  • Page 17: Address Setting

    6.2 Address Setting If you use a universal DMX controller to control the units, you have to set DMX address from 1 to 512 so that the units can receive DMX signal. Press the MENU button to enter menu mode, select DMX Settings, press the ENTER button to confirm, use the UP/DOWN button to select DMX Address, press the ENTER button to confirm, the present address will blink in the display, use the UP/DOWN button to adjust the address from 001 to 512, press the ENTER button to store.
  • Page 18 147 Channels (Mode 1): CHANNEL VALUE FUNCTION RED1 000-255 0%100% GREEN1 000-255 0%100% BLUE1 000-255 0%100% WHITE1 000-255 0%100% RED2 000-255 0%100% GREEN2 000-255 0%100% BLUE2 000-255 0%100% WHITE2 000-255 0%100% …… …… …… RED36 000-255 0%100% GREEN36 000-255 0%100% BLUE36 000-255 0%100%...
  • Page 19 17 Channels (Mode 2): CHANNEL VALUE FUNCTION RED (RING 1) 000-255 0%100% GREEN (RING 1) 000-255 0%100% BLUE (RING 1) 000-255 0%100% WHITE (RING 1) 000-255 0%100% RED (RING 2) 000-255 0%100% GREEN (RING 2) 000-255 0%100% BLUE (RING 2) 000-255 0%100% WHITE (RING 2)
  • Page 20 090-094 LEE 353-Lighter Blue 095-099 LEE 118-Light Blue 100-104 LEE 116-Medium Blue Green 105-109 LEE 124-Dark Green 110-114 LEE 139-Primary Green 115-119 LEE 089-Moss Green 120-124 LEE 122-Fern Green 125-129 LEE 738-JAS Green 130-134 LEE 088-Lime Green 135-139 LEE 100-Spring Yellow 140-144 LEE 104-Deep Amber 145-149...
  • Page 21 070-079 Null 080-089 Null 090-099 Null 100-109 Null 110-119 Null 120-129 Null 130-139 Null 140-179 Null 180-189 Dimmer Speed Fast 190-199 Dimmer Speed Smooth 200-209 Null 210-219 Null 220-229 Null 230-255 Null 11 Channels (Mode 3): CHANNEL VALUE FUNCTION 000-255 0%100% GREEN 000-255...
  • Page 22 090-094 LEE 353-Lighter Blue 095-099 LEE 118-Light Blue 100-104 LEE 116-Medium Blue Green 105-109 LEE 124-Dark Green 110-114 LEE 139-Primary Green 115-119 LEE 089-Moss Green 120-124 LEE 122-Fern Green 125-129 LEE 738-JAS Green 130-134 LEE 088-Lime Green 135-139 LEE 100-Spring Yellow 140-144 LEE 104-Deep Amber 145-149...
  • Page 23 104-111 Effect 13 112-119 Effect 14 120-127 Effect 15 128-135 Effect 16 136-143 Effect 17 144-151 Effect 18 152-159 Effect 19 160-167 Effect 20 168-175 Effect 21 176-183 Effect 22 184-191 Effect 23 192-199 Effect 24 200-207 Effect 25 208-215 Effect 26 216-223 Effect 27...
  • Page 24 148-156 Letter-O 157-165 Letter-P 166-174 Letter-Q 175-183 Letter-R 184-192 Letter-S 193-201 Letter-T 202-210 Letter-U 211-219 Letter-V 220-228 Letter-W 229-237 Letter-X 238-246 Letter-Y 247-255 Letter-Z LETTER a to z 000-021 No Function 022-030 Letter-a 031-039 Letter-b 040-048 Letter-c 049-057 Letter-d 058-066 Letter-e 067-075 Letter-f...
  • Page 25 190-231 Fast Open Slow Close 232-239 Open 240-247 Random Strobe 248-255 Open DIMMER 000-255 0%100% 000-255 DIMMER FINE SPECIAL FUNCTION 000-029 Null 030-039 Dimmer Curve Linear 040-049 Dimmer Curve Square Law 050-059 Dimmer Curve Inv SQ Law 060-069 Dimmer Curve S 070-079 Null 080-089...
  • Page 26 44 Channels (Mode 5): CHANNEL VALUE FUNCTION LED1 000-255 0%100% LED2 000-255 0%100% LED3 000-255 0%100% LED4 000-255 0%100% LED5 000-255 0%100% LED6 000-255 0%100% LED7 000-255 0%100% LED8 000-255 0%100% LED9 000-255 0%100% LED10 000-255 0%100% LED11 000-255 0%100% LED12 000-255 0%100%...
  • Page 27 LED20 000-255 0%100% LED21 000-255 0%100% LED22 000-255 0%100% LED23 000-255 0%100% LED24 000-255 0%100% LED25 000-255 0%100% LED26 000-255 0%100% LED27 000-255 0%100% LED28 000-255 0%100% LED29 000-255 0%100% LED30 000-255 0%100% LED31 000-255 0%100% LED32 000-255 0%100% LED33 000-255 0%100% LED34...
  • Page 28 035-039 LEE 179-Chrome Orange 040-044 LEE 104-Deep Amber 045-049 LEE 100-Spring Yellow 050-054 LEE 088-Lime Green 055-059 LEE 738-JAS Green 060-064 LEE 122-Fern Green 065-069 LEE 089-Moss Green 070-074 LEE 139-Primary Green 075-079 LEE 124-Dark Green 080-084 LEE 116-Medium Blue Green 085-089 LEE 118-Light Blue 090-094...
  • Page 29 050-054 LEE 120-Deep Blue 055-059 LEE 079-Just Blue 060-064 LEE 132-Medium Blue 065-069 LEE 200-Double CT Blue 070-074 LEE 161-State Blue 075-079 LEE 201-Full CT Blue 080-084 LEE 202-Half CT Blue 085-089 LEE 117-Steel Blue 090-094 LEE 353-Lighter Blue 095-099 LEE 118-Light Blue 100-104 LEE 116-Medium Blue Green...
  • Page 30 040-047 Effect 05 048-055 Effect 06 056-063 Effect 07 064-071 Effect 08 072-079 Effect 09 080-087 Effect 10 088-095 Effect 11 096-103 Effect 12 104-111 Effect 13 112-119 Effect 14 120-127 Effect 15 128-135 Effect 16 136-143 Effect 17 144-151 Effect 18 152-159 Effect 19...
  • Page 31 076-084 Letter-G 085-093 Letter-H 094-102 Letter-I 103-111 Letter-J 112-120 Letter-K 121-129 Letter-L 130-138 Letter-M 139-147 Letter-N 148-156 Letter-O 157-165 Letter-P 166-174 Letter-Q 175-183 Letter-R 184-192 Letter-S 193-201 Letter-T 202-210 Letter-U 211-219 Letter-V 220-228 Letter-W 229-237 Letter-X 238-246 Letter-Y 247-255 Letter-Z LETTER a to z 000-021 No Function...
  • Page 32 247-255 Letter-z STROBE 000-007 Close 008-015 Open 016-131 Strobe from Slow to Fast 132-139 Open 140-181 Fast Close Slow Open 182-189 Open 190-231 Fast Open Slow Close 232-239 Open 240-247 Random Strobe 248-255 Open DIMMER 000-255 0%100% DIMMER FINE 000-255 SPECIAL FUNCTION 000-029 Null...
  • Page 33: Error Information

    144 Channels (Mode 6): CHANNEL VALUE FUNCTION RED1 000-255 0%100% GREEN1 000-255 0%100% BLUE1 000-255 0%100% WHITE1 000-255 0%100% RED2 000-255 0%100% GREEN2 000-255 0%100% BLUE2 000-255 0%100% WHITE2 000-255 0%100% …… …… …… RED36 000-255 0%100% GREEN36 000-255 0%100% BLUE36 000-255 0%100%...
  • Page 34: Troubleshooting

    8. Troubleshooting Following are a few common problems that may occur during operation. Here are some suggestions for troubleshooting: A. The unit does not work and no light 1. Check the connected power. 2. Measure the voltage. 3. Check the power indicator to see whether it can be lit up or not. B.