4. How To Control The Unit
You can operate the unit by DMX controller:
No need to turn the unit off when you change the DMX address, as new DMX address setting will
be affected at once. Every time you turn the unit on, it will show
on the display After that
the unit will be ready to receive DMX signal or run the built in programs.
4.1 DMX Controller
Use universal DMX controller to control the units, you have to set DMX address from 1 to 512
channel so that the units can receive DMX signal.
Press the MENU button up to when the
is showing on the display. Pressing the NTER
button and the display will blink. Use the DOWN and UP button to change the DMX512 address.
Once the address has been selected, press and keep the ENTER button pressed up to when the
display stops blinking or storing automatically 8 seconds later. To go back to the functions without
any change press the MENU button again.
DMX 512 Configuration:
BW-903 CW AR:
12E