Port Configuration
Figure 4 PowerEdge R640 and R740xd PCI slots, integrated NICs and BMC port locations
1
2
3
BMC
Integrated
(iDRAC)
NICs
4
5 6
7
8
1
2
3
iDRAC
BMC
Integrated
(iDRAC)
NICs
Data cables are connected to two switches, for high availability, via the nodes' 10 G or
25 G ports. Management interfaces are connected to a switch on a separate
management network using onboard and BMC (iDRAC) ports.
In ESXi environments, the AMS/Discovery server must be on the same Layer 2
network as the ESXi management ports. This allows the use of the Broadcast protocol
for initial IP address configuration.
The BMC (iDRAC) IP address can reside on a different subnet and/or VLAN, and the
only requirement from the BMC (iDRAC) side is that the AMS (when used) must have
a routable IP Path to the BMC (iDRAC) IP address on the node.

PowerEdge R640 and R740xd port designations - ESXi

Server node port designations in an ESXi-based ScaleIO system.
Connect the cables and configure the system as shown in the following tables,
depending on the server type and (architecture, when relevant).
PowerEdge R740xd Servers
PowerEdge R640 and R740xd port designations - ESXi
43