Download Print this page
Dell EMC ScaleIO Ready Node 14G Inspection Manual
Dell EMC ScaleIO Ready Node 14G Inspection Manual

Dell EMC ScaleIO Ready Node 14G Inspection Manual

Hide thumbs Also See for EMC ScaleIO Ready Node 14G:

Advertisement

Quick Links

Maintenance
EMC ScaleIO Ready Node 14G
Server Inspection Guide
P/N 302-004-342
REV 01
October 2017
Preface................................................................................................................... 2
Introduction............................................................................................................ 3
Prerequisites.......................................................................................................... 5
Checklist...............................................................................3
disks................. 6

Advertisement

loading

Summary of Contents for Dell EMC ScaleIO Ready Node 14G

  • Page 1: Table Of Contents

    Maintenance EMC ScaleIO Ready Node 14G Server Inspection Guide P/N 302-004-342 REV 01 October 2017 Preface........................2 Introduction......................3 Hardware Installation Checklist................3 Prerequisites......................5 Verify the status of the system hardware, storage controller, and disks....6...
  • Page 2: Preface

    Maintenance Preface As part of an effort to improve its product lines, EMC periodically releases revisions of its software and hardware. Therefore, some functions described in this document might not be supported by all versions of the software or hardware currently in use. The product release notes provide the most up-to-date information on product features.
  • Page 3: Introduction

    Server Inspection Guide Braces enclose content that the user must specify, such as x or y or Ellipses indicate nonessential information omitted from the example Where to get help EMC support, product, and licensing information can be obtained as follows: Product information For documentation, release notes, software updates, or information about EMC products, go to EMC Online Support at https://support.emc.com.
  • Page 4 Maintenance Installation Type: New Installation Add-On Revisit Other (specify) ___________________ Install Start Date: Install End Date: ScaleIO Hardware Info ScaleIO Node Type Check all that apply: 1U1N Qty: 2U1N Qty: Mgmt. Server Network Equipment: Mgmt Switch Qty: Data Switch Qty: Mgmt.
  • Page 5: Prerequisites

    Server Inspection Guide All PSUs power-on Rear fan-spin (feel air-flow) PSU has no amber LED on Server has no amber LED on HDD/SSD has no amber LED on (reseat and reset the server) Attach KVM, reset/power- cycle server and note down error displayed, if any are shown.
  • Page 6: Verify The Status Of The System Hardware, Storage Controller, And Disks

    Procedure <BMC/iDRAC_IP_address> . 1. From a browser, go to http:// The DELL Console Login window is displayed. 2. Type the user name and password, then click Login. The Dashboard displays the high-level status of all hardware devices in the System Health pane.
  • Page 7 Server Inspection Guide If the driver and firmware versions do not match the matrix, you must update them. See "Updating the BIOS, firmware and settings" in the ScaleIO Ready NodeAMS Deployment Guide . Verify the status of the system hardware, storage controller, and disks...
  • Page 8 FITNESS FOR A PARTICULAR PURPOSE. USE, COPYING, AND DISTRIBUTION OF ANY DELL SOFTWARE DESCRIBED IN THIS PUBLICATION REQUIRES AN APPLICABLE SOFTWARE LICENSE. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be the property of their respective owners. Published in the USA.