Dell EMC ScaleIO Ready Node 14G Manual page 59

Hide thumbs Also See for EMC ScaleIO Ready Node 14G:
Table of Contents

Advertisement

Removing all the existing VDs from the node
l
Setting up the controller card boot parameter
l
Procedure
1. Log in to the node.
2. Display the disk information on the node:
/opt/lsi/perccli/perccli /c0/eall/sall show
Output similar to the following is displayed:
The output shows the following:
Enclosure ID (EID): Used in a later step when creating VDs
l
Slot ID (SLT) of each drive: Used in a later step when creating VDs
l
Drive type: Displays SSD or HDD as the device type. (SSD drives are smaller
l
—744 GB in this case.)
Drive state: Should be UGood (unused and good)
l
3. Verify that the VDs exist on the node:
/opt/lsi/perccli/perccli /c0/vall show
Output similar to the following is displayed:
If the output confirms that VDs exist on the node, perform the next step to
remove them. Otherwise, skip the step.
4. Remove all existing VDs from the node:
/opt/lsi/perccli/perccli /c0/vall del
The VDs are removed.
5. Set the controller card boot parameter:
/opt/lsi/perccli/perccli /c0 set bootwithpinnedcache=on
Preparing Disks to add to a ScaleIO SDS
Verify the storage and disk controller status
59